| Input Voltage |
85 ~ 264Vac 120 ~ 370Vdc |
| Input Frequency |
47 ~ 63Hz |
| Input Current |
0.35A/115Vac 0.25A/230Vac |
| Inrush Current |
50A/ 230Vac, cold start |
| Leakage Current |
<2mA/ 240Vac |
| Set Up, Rise Time |
1000ms, 30ms/230Vac 1000ms, 30ms/115Vac at full load |
| Hold Up Time |
70ms/230Vac 15ms/115Vac at full load |
| Over Load Protection |
Above 105% rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Shut off o/p voltage, clamping by zener diode |
| Over Temperature Protection |
U1 Tj 140°C typically (U1) detect on main control IC |
|
Shut down o/p voltage, recovers automatically after temperature goes down |
| Working Temperature |
-20°C to +70°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-40°C to +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.03%/°C (0 ~ 50°C) |
| Vibration |
10 ~ 500Hz, 5G 10min./1 cycle, period for 60min. each along X,Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| Safety Standards |
UL60950-1, TUV EN60950-1 approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; |
|
EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, light industry level, criteria A |
| MTBF |
1608.8Khrs min. MIL-HDBK-217F (25°C) |