| Input Voltage |
85 ~ 264Vac |
| Frequency |
47~63Hz |
| Efficiency |
77% typically |
| Power Factor |
90% minimum |
| Input VA at Standby |
30VA typically at 100Vac / 60VA typically at 240Vac, 5Vsb rated load |
|
10VA typically at 100Vac / 40VA typically at 240Vac, 5Vsb no load |
| Over Current Protection |
Hold-down; 3.3V, 5V & +12V latch locked. Manual recovery. |
|
-12V fold-back, automatic recovery. 5VSB hold-down, automatic recovery |
| Over Voltge Protection |
Re-power on/off to recover |
| Operating Temperature |
0°C ~ 60°C |
| Operating Humidity |
10 ~ 90% RH non condensing |
| Storage Temperature, Humidity |
-20°C ~ +70°C; 10 ~ 95% RH |
| Vibration |
10 ~ 55Hz, 2G, 10 sweep cycles in X, Y, Z axes |
| Insulation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 50M min. / 500VDC |
| Dielectric Strength |
AC 1.5KV for one minute between Input and Chassis/Outputs |
| Leakage Current |
0.5mA max. at 100V AC / 1mA max. at 200V AC |
| Safety Standards |
UL60950-1, CSA60950-1(c-UL), and EN60950-1(NEMKO) Certified. |
| EMC |
Compliance to IEC61000-4-2 Test Level 3; VCCI, FCC part 15 CISPR 22; EN55022 Class A; |
|
IEC61000-3-2 (Ver. 2.1) Class D |
| MTBF |
100,000 hours or longer |