| Input voltage |
Universal full range 90 ~ 264 VAC |
| Input frequency |
47 ----- 63Hz |
| Input current |
SPP-E020: <0.5A@100V AC input. SPP-E030: <0.8A@100V AC input. |
|
SPP-E040: <1.3A@100V AC input. SPP-E050~051: <1.5A@100V AC input. |
| Inrush current |
<20A@115V / <40A@230V AC input. |
| Leakage current |
<1.5mA@264V AC input |
| Short circuit protection |
Go into 'HICCUP MODE'. Auto recovery when fault condition has been removed. |
| Rise time |
<20mS |
| Hold up time |
>20mS@230V |
| Setup time |
<800mS@115V / <300mS@230V AC input |
| Temperature |
Operating: -10°C ~70°C; De-rating: 50°C ~70°C : 2.5%/°C. Storage: -10% ~+75°C |
| Humidity |
Operating: 20% ~ 85%; Storage: 10% ~ 95% (non condensing) |
| MTBF |
150K hours |
| Safety standard |
UL 1950 2nd, CSA 22.2 No.950, IEC 60950, EMKO-TSE(74-SEC)207/94 approved. TUV EN 60950-1st standard. |
| EMI |
EN 55022 CLASSB, FCC CFR 47PART 15 CLASS B, CNS 13438 CLASS B |
| EMS |
EN 55024 : EN 61000-4-2,3,4,5,6,8,11. |