| Input Voltage |
Universal input 90 ~ 264 Vac |
| Input Frequency |
47 ~ 63Hz |
| Input Current |
<3.0A @ 100Vac input. |
| Inrush Current |
<30A @ 115V, <60A @ 230Vac input |
| Leakage Current |
<1.5mA@264Vac input |
| Rise Time |
<60mS |
| Hold Up Time |
>20mS@ 230V |
| Over Load Protection |
Over 105% ~ 180% of rating, shutdown & latch off. |
| Short Circuit Protection |
Shutdown and latch off. Turn off and on to restart |
| Power Good Signal |
Power on within 100~500ms, high level TTL signal release. |
| PS-ON Signal |
P/S ON: PS-ON=Low or <0.8V, P/S OFF: PS-ON=Hi or >2V |
| Working Temperature |
0°C ~ 70°C; De-rating: 45°C ~ 70°C : 2.5%/°C. |
| Working Humidity |
20% ~ 85% (non condensing) |
| Storage Temperature, Humidity |
-20°C ~ +85°C, 10% ~ 95% (non condensing) |
| Cooling |
10CFM DC ball bearing fan |
| Safety Standards |
UL 60950 3rd, CSA C22.2 No 60950 3rd, TUV EN 60950-1, IEC 60950-1, EMKO-TSE (74-SEC) 207/94 |
| EMI Standards |
EN 55022 CLASS B : EN61000-3-2,3 , FCC CFR 47 PART 15 CLASS B, CNS 13438 CLASS B |
| EMS Standards |
EN 55024 : EN 61000-4-2,3,4,5,6,8,11 |
| Cooling |
Forced airflow cooling with a 10 CFM (MIN.) DC FAN. |
| M.T.B.F |
143k hours |