| Input Voltage |
85 to 264Vac 120 to 375Vdc |
| Input Frequency |
47 to 63Hz |
| Input Current |
0.8A max. at 100Vac input, full load |
| Inrush Current |
30A max. at 115Vac input, full load, 50A max. at 230Vac input, full load |
| Leakage Current |
1.0mA max. at 264Vac input |
| Over Load Protection |
Over 105% ~ 200% of rating |
|
recovers automatically after fault condition has been removed |
| Short Circuit Protection |
Auto recovers once fault condition removed |
| Rise Time |
20mS max |
| Hold Up Time |
40mS min. at 230Vac |
| Set Up Time |
2.0s max. at 115Vac input 0.8s max. at 230Vac input |
| Cooling |
Natural Cooling |
| Green Mode Function |
When zero loading, the input dissipation is below 0.75W. |
| Operating Temperature |
-25°C ~ 70°C ; De-rating: -25°C ~ -10°C : 2.5%/°C / 50°C ~ 70°C : 2.5%/°C |
| Operating Humidity |
20% ~ 85% (non condensing) |
| Storage Temperature, Humidity |
-25°C ~ 75°C, 10% ~ 95% (non condensing) |
| Safety Approvals |
UL 60950 3rd, CSA C22.2 No.60950 3rd , TUV EN 60950, IEC 60950, EMKO-TSE (74-SEC)207/94 approved |
| EMC |
EN 55022 CLASS B, FCC CFR 47 PART 15 CLASS B, CNS 13438 CLASS B |
|
EN 55024:EN 61000-4-2,3,4,5,6,8,11 |
| MTBF |
450K hours |