| Input Voltage |
85 ~ 264Vac; 120~370Vdc |
| Input Frequency |
47 ~ 63Hz |
| Input Current |
0.65A/115Vac 0.4A/230Vac |
| Inrush Current |
32A, cold start |
| Leakage Current |
<0.5mA/240Vac |
| Setup, Rise Time |
250mS, 50mS/230Vac 250mS, 30mS/115Vac at full load |
| Hold Time |
100mS/230Vac 16mS/115Vac at full load |
| Over Load Protection |
>105% rated output power |
|
Hiccup mode, recovers automatically once fault condition removed |
| Over Voltage Protection |
Shuts down output voltage, re-power on to recover |
| Over Temperature Protection |
Tj 135°C typically (U1) Detect on main control IC |
|
Shut down output voltage, auto recovery once temperature goes down |
| Working Temperature |
-10°C to +60°C, refer to derating curve |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C to +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.03%/°C (0 ~ 50°C) on primary output |
| Vibration |
10 ~ 500Hz, 2G 10min./1 cycle, Period for 60 mon. each along X, Y, Z axes |
| Safety Standard |
UL60950-1, TUV EN60950-1 Approved |
| Withstand Voltage |
I/P-0/P :3KV, I/P-FG:1.5KV, O/P-FG:0.2KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100MOhms/500VDC |
| EMC Standards |
EN55022 (CISPR22) Class B, EN61000-3-2,3 |
|
EN61000-4-2,3,4,5, Light industry level, Criteria A |
| MTBF |
507.9Khrs min. MIL-HDBK-217F (25°C) |