| Input Voltage |
100Vac ~ 264Vac |
| Input Frequency |
47 ~ 63Hz |
| Input Current |
5A at 240Vac |
| Inrush Current |
100A peak, cold start |
| Maximum Power |
250W |
| Peak Power |
275W |
| Line Regulation |
±1%, typically |
| Load Regulation |
±5%, typically |
| Cross Regulation |
±5%, typically |
| Dielectric Withstand Voltage |
I/P-FG, I/P-O/P: 1800Vac, 1sec. |
| Efficiency |
Over 72% at normal input voltage |
|
74% at AC 100v 60Hz ; 76% at AC 230v 50Hz (typical) |
| Output Power Protection |
135% total power maximum, shut down and latch off |
| Over Voltage Protection |
Shutdown and Latch off the group 1 outputs |
| Short Curcuit Protection |
Short between any output of group 1 will shut down all group 1 |
|
Short at group 2 will shutdown both group 1 & group 2 |
| Reset After Shutdown |
The power supply will return to normal operation once fault removed |
|
and power switch has been cycled off/on with a min off time of 20mS |
| PFC |
>0.95 at 220Vac, >0.98 under full load |
| Operating Temperature |
0°C to 40°C |
| Operating Humidity |
20% to 85% RH |
| Storage Temperature, Humidity |
-40°C to +85°C, 10% to 95% |
| MTBF |
100,000 hours |
| Safety |
Confirms to EN60950 Standards: TUV, CB, cUL |
| EMC |
EN50081-1, EN55024, FCC Class B |
|
EN55024, EN61000-3-2, CE |