| Input Voltage |
90 ~ 264Vac; 127 ~ 370Vdc |
| Input Frequency |
47 ~ 63Hz |
| Power Factor |
PF>0.93/230Vac PF>0.97/115Vac at full load |
| Input Current |
3A/115Vac 1.5A/230Vac |
| Inrush Current |
55A/230Vac, cold start |
| Leakage Current |
<3.5mA/240Vac |
| Set Up, Rise Time |
2500ms, 60ms/115Vac 1200ms, 60ms/230Vac |
| Hold Up Time |
30ms at full load |
| Over Load Protection |
CH1: 105 ~ 170%rated output power |
|
Normally work within 10 sec and then shut down, re-power on to recover; >180% rated power |
|
or short circuit, constant current limiting within 10 sec and then shut down, re-power on to recover |
| Over Voltage Protection |
Shut down o/p voltage, re-power on to recover for CH1; |
|
Hiccup mode, recovers automatically afer fault condition is removed for CH2.(by zener diode clamp) |
| Over Temperature Protection |
95°C ±5°C Detect on heatsink of power transistor |
|
Shut down o/p voltage, recovers automatically after temperature goes down |
| Remote Control |
CN52 : Open=CH1 & CH2 power on ; Short = CH1 power off, CH2 power on. |
|
when CH2 is malfunction, CH1 will be shut down |
| Working Temperature |
-20°C to +70°C (refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C ~ +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.05%/°C (0 ~ 50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X,Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 25°C 70%RH |
| Safety Standards |
UL60950-1,TUV EN60950-1 Approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3 |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, Heavy industry level, criteria A |
| MTBF |
150.4Khrs min. MIL-HDBK-217F (25°C) |
| Dimensions |