| Input Voltage |
AC 115V / 230V auto sensing or universal full range |
| Frequency |
47 ----- 63 Hz |
| Input Current |
<6.0A @ 115V AC input, <3.5A @ 230V AC input, full load condition |
| Inrush Current |
<40A@115V / <80A@230V AC input, full load condition. Cold start at 25°C ambient |
| Leakage Current |
<1.5mA@264V AC input |
| Over Load Protection |
Over 105% ~ 150% of rating, shutdown |
| Short Circuit Protection |
Shutdown |
| Rise time |
<20mS |
| Hold up time |
>20mS@230V |
| TTL Signal |
Power Good Signal, PS-ON Signal |
| Cooling |
Two 16 CFM (min.) DC ball bearing Fan |
| Temperature |
Operating: 0~70°C; derating: 45°C ~70°C : 2.5%/°C. Storage: -10~+75°C |
| Humidity |
Operating: 20% ~ 85%; Storage: 10% ~ 95% (non condensing) |
| M.T.B.F. |
166K hours |
| SAFETY |
UL 60950, CSA C22.2 No.60950, IEC 60950, EMKO-TSE |
| EMI |
FCC CFR 47 PART 15 CLASS B, EN 50081-1, CNS 13438 CALSS B. |
| EMS |
EN 50082-1 (1997) |