SDX-300-96 - 300W PS2 DC-DC ATX Power Supply
Features
- High efficiency, high reliability
- 2:1 input range
- input and output isolation
- Soft start function, low inrush current
- input over voltage and under voltage protection
- Over load, over voltage & short circuit protection
- +3.3V, +5V main output remote sensing
- Meet intel ATX 2.01 / 2.03
- FR4 glass epoxy double side circuit board, meet UL-94V0, which could work in an environment with high vibration
- Built-in long life ball bearing fan
- 100% 50°C burn-in test
General Specifications
| Input Voltage | 72V~144V DC . |
|---|---|
| Input Current | <5.9A@72VDC. |
| Inputprotection | Ceramic fuse, 8A / 250V. |
| Over Load Protection | Over 105% ~ 150% of rating, shutdown |
| Short Circuit Protection | Shutdown |
| Rise time | <20Ms |
| TTL Signal | Power Good Signal , PS-ON Input Signal . |
| Cooling | Built-in a 36CFM DC ball bearing fan. |
| Temperature | Operating: -10~70°C; Derating: 45°C ~70°C : 2.0%/°C; Storage: -10~+75°C |
| Humidity | Operating: 20% ~ 85%; Storage: 10% ~ 95% (non condensing). |
| M.T.B.F. | 188K . |
| EMI Standards | FCC CFR 47 PART 15 CLASS B、EN 55022 CLASS B、CNS 13438 CALSS B. |
| EMS Standards | EN 55024:EN 61000-4-2,3,4,5,6,8 |
SDX-300-96 Specifications
| Part Number | Voltage (max/rated) | Current (amps) | Power (watts) | R&N (mV) | Efficiency (%) |
|---|---|---|---|---|---|
| SDX-300-96 | 3.3V | 30A | 300W | 50mV | 72% |
| 5V | 35A | 50mV | |||
| 12V | 18A | 120mV | |||
| -5V | 0.5A | 70mV | |||
| -12V | 1A | 150mV | |||
| 5V | 2A | 50mV |