| Input Voltage |
90 ~ 264Vac |
| Input Frequency |
47~63Hz |
| Input Current |
5A max |
| Inrush Current |
100A max, cold start |
| Hold Up Time |
12mS typically |
| Dynamic DC Output |
±10% Max. Excursion for 50% to 100% or 100% to 50% load change with return to regulation in 0.5mS |
| Total Power Protection |
Total power 135% max with shut-down and latch off protection |
| Over Voltage Protection |
Shut down & Latch OFF |
| Short Circuit Protection |
Shut down, re-power to recover |
| Power Good Signal |
open collector +5Vdc, TTL compatible |
| Efficiency |
Over 80% at nominal voltage |
| Energy Star Mode |
Over 50% at 30W max power consumption with 15.0W load or more delivered to DC |
| Operating Temperature |
0°C ~ 50°C |
| Operating Humidity |
20% ~ 85% |
| Storage Temperature, Humidity |
-40°C ~ +85°C, 10%~95% |
| Active PFC |
Harmonic current meets IEC1000-3-2 / EN61000-3-2 standards. PFC >0.95 at full load. |
| Safety Standards |
Conform to IEC950 (EN60950) standards: TUV, CB, C-UL, S |
|
|
| EMC |
Compliance to CE EN50081-1(1992) , EN55024(1998) & FCC (B) regulation, C Tick |
|
EN55024(1998); EN61000-3-2(2000) |
| Cooling |
80mm DC Fan, 30 CFM |
| MTBF |
Over 100,000 hours at 25 Deg C. excluding the DC Fan |