Sunpower UKSunpower UK
Sunpower UK Product Search

Advanced Search

Featured Product

Request Information

Clipbook

You haven't added any products to your clip book yet.

Add this product to your ClipBook

BS-EN-ISO 9001:2000 certified BS-EN-ISO 9001:2000 certified
We make every effort to ensure the information provided is accurate however we can not be held responsible for errors. Specifications are subject to change without notice; please ensure you conduct testing to ensure the product is suitable for your intended application.

New Products

300W PFC Single Output Battery Charger

300W PFC Single Output Battery Charger Designed for lead acid batteries featuring 3 stage charging characteristics and the automated...
All New Products

In Development

80W Green Mode Single Output AC-DC Desktop Adapter

80W Green Mode Single Output AC-DC Desktop Adapter Designed for both medical and ITE applications SNP-A08 Series features no load input power of <0.3...
All Products in Development

DR-60-5 - 32.5W 5V 6.5A Class II DIN Rail Power Supply

DR-60 Series Product Image - DR-60-5 - 32.5W 5V 6.5A Class II DIN Rail Power Supply

Features

  • Universal AC input/Full range
  • Short circuit/Over Load/Over voltage protection
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • UL 508 (industrial control equipment) approved
  • Isolation Class II
  • LED indicator for power on
  • 100% full load burn-in test

Standards

CBTUVCSUUSCE

Case Details

78 x 93 x 56mm

General Specifications

Input Voltage 88 ~ 264VAC 124 ~ 370VDC
Input Frequency 47~63Hz
AC Current 1.2A/115VAC 0.8A/230VAC
Inrush Current (max.) 18A/115VAC 36A/230VAC, cold start
Setup, Rise Time 100ms, 30ms/230VAC 200ms, 30ms/115VAC at full load
Hold Time (Typ.) 100ms/230VAC 23ms/115VAC at full load
Over Load Protection 105 ~ 160% rated output power
Constant current limiting, recovers automatically after fault condition is removed
Over Voltage Protection Shut down o/p voltage, re-power on to recover
Working Temperature -20°C to +60°C (Refer to output load derating curve)
Working Humidity 20% to 90% RH non-condensing
Storage Temp., Humidity -40°C to +85°C , 10% to 95% RH
Temp. Coefficient ±0.03%/°C (0°C to 50°C)
Vibration 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Safety Standards UL60950-1, TUV EN60950-1 Approved, Design refer to EN50178
Withstand Voltage I/P-O/P:3KVAC
Isolation Resistance I/P-O/P:100M Ohms/500VDC
EMC Compliance to EN55011,EN55022 (CISPR22) Class B, EN61000-3-2,-3
EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-1, EN61204-3 Light industry, criteria A
MTBF 216.2K hrs min. MIL-HDBK-217F (25°C)
Dimensions 78 x 93 x 56mm

DR-60-5 Output Data

DC Voltage Rated Current Current Range Rated Power R&N Volt. Adj. Tol. Line Reg. Load Reg. Eff. OVP
5V 6.5A 0 ~ 6.5A 32.5W 80mV 4.75 ~ 5.5V ±2.0% ±1.0% ±1.0% 76% 5.75 ~ 6.75V