| Input voltage |
AC input 90 ~ 264V, universal full range. |
| Input frequency |
47 ~ 63 Hz |
| Input current |
<8A@100VAC. AC input single module full load condition. |
| Inrush current |
<40A@115V; <80A@230V.Single Module AC input full load condition. Cold start at 25°C ambient. |
| Leakage current |
<2mA @ 264V AC input |
| Power Factor |
Meet IEC 1000-3-2 class D, P.F.>0.95 (optional) |
| Max Power |
+3.3V & +5V: Single Module:<200W; Dual Module:<375W. -5V & -12V: Single Module:<12W |
|
Total output of dual module: 500W max continuously |
| Over Load Protection |
Output over 105% ~ 150% of rated load, power supply will shutdown and latch. |
| Over Temperature Protection |
Shutdown and latch when power supply's temperature reach 95°C (Optional) |
| Short Circuit Protection |
Shutdown and latch. |
| Rise time |
<20mS |
| Hold up time |
>20mS@230V |
| TTL Signal |
Power good signal (for 4 & 6 output models) / PS-ON signal: Hi for power supply off, |
|
low for power supply on. (for 6 output models) |
| Alarm |
Power fail alarm; Fan fail alarm |
| Cooling |
A 37CFM (min.) DC ball bearing Fan in each module |
| Temperature |
Operating: 0 ~70°C; derating: 45°C ~70°C : 2%/°C. Storage: -10~+75°C |
| Humidity |
Operating: 20% ~ 85%; Storage: 10% ~ 95% (non condensing) |
| M.T.B.F |
108K hours (for non PFC models) |
| Safety |
UL 60950, CSA C22.2 No.60950, TUV EN 60950, IEC 60950, EMKO-TSE (74-SEC)207/94 Certified |
| EMI |
FCC CFR 47 PART 15 CLASS B, EN 50081-1, CNS 13438 CLASS B. |
| EMS |
EN 50082-1 (1997) |