| Input Voltage |
90 ~ 305 Vac |
| Input Frequency |
47 ~ 63Hz |
| Input Current |
Max 0.43A/110Vac 0.22A/220Vac, full load |
| Inrush Current |
20A/230Vac 25°C, cold start |
| Power Factor |
0.99/110Vac 0.92/220Vac |
| Ripple & Noise |
10% of Voltage |
| Line Regulation |
±2% |
| Load Regulation |
±5% |
| Turn-on Delay |
1.7 secs/110Vac 0.7 secs/220Vac |
| Output Overshoot/Undershoot |
10%, when power on or off |
| No Load Power Dissipation |
<3W |
| Over Voltage Protection |
Hiccup mode. The power supply shall auto-recover when the fault condition is removed |
| Over Load Protection |
1.25Po |
|
Hiccup mode. The power supply shall auto-recover when the fault condition is removed |
| Short Circuit Protection |
No damage shall occur when any output operating in a short circuit condition. |
|
The power supply shall auto-recover when the fault condition is removed. |
| Operating Temperature |
-35°C ~ +70°C |
| Operating Humidity |
10% to 100% RH |
| Storage Temperature, Humidity |
-40°C ~ +85°C, 5% to 100% RH |
| Safety Standards |
EN 61347-1, EN61347-2-13, UL8750 |
|
Compliance to UL1310 Class 2, UL1012 UL935, CAN/CSA-C22.2 No. 0, |
|
CSA-C22.2 No. 107.1, CSA-C22.2 No. 250.0 |
| EMC |
Compliance to EN 55015, EN 61000-3-2, EN 61000-3-3, EN 61547, |
|
EN 61000-4-2, 3, 4, 5, 6, 8, 11 |
| MTBF |
541,000 hours 110Vac input, 2900mA model, 80% load and 25°C ambient temperature (MIL-HDBK-217F) |
| Lifetime |
87,000 hours 2900mA model, 110Vac input, 80% load at 45°C ambient temperature |
| Dimming Control |
The dimmer control may be operated from either a potentiometer or from an input signal of 0 – 10 Vdc |