| Voltage Range |
88 ~ 264Vac 125 ~ 373Vdc (Withstand 300Vac surge for 5sec. Without damage) |
| Frequency |
47 ~ 63Hz |
| Input Current |
0.8A/115Vac 0.55A/230Vac |
| Inrush Current |
36A at 230Vac max., cold start |
| Leakage Current |
<2mA at 240Vac |
| Setup, Rise Time |
500ms, 30ms/230Vac 1200ms, 30ms/115Vac at full load |
| Hold Up Time |
80mS/230Vac 15mS/115Vac at full load |
| Over Load Protection |
110 ~ 150% rated output power |
|
Hiccup mode, recovers automatically after fault condition removed |
| Over Voltage Protection |
Hiccup mode, recovers automatically after fault condition is removed |
| Working Temperature |
-25°C to +70°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temp., Humidity |
-40°C to +85°C, 10 ~ 95% RH |
| Temp. Coefficient |
±0.03%/°C (0 ~ 50°C) |
| Vibration |
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| Safety Standards |
UL60950-1, TUV EN60950-1 Approved |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) Heavy Industry Level, A |
| MTBF |
249Khrs min. MIL-HDBK-217F (25?C) |