| Input Voltage |
9.5Vdc ~ 18Vdc (Typically 12V) |
| Input Current |
<10A@9.5Vdc |
| Input Protection |
Ceramic fuse 15A/125V |
| Over Voltage Protection |
Unit will shutdown if an over voltage conditions occurs. Auto recovery once fault is removed |
| Over Load Protection |
105% ~ 180% of rated output. Auto recovery |
| Short Circuit Protection |
Unit will shutdown if a short circuit conditions occurs. Auto recovery once fault is removed |
| Rise Time |
<20ms |
| Cooling |
Natural cooling |
| Operation Temperature |
0°C to +70°C, derating: 50°C~70°C: 2.5%/°C |
| Storage Temperature |
-10°C to +75°C |
| Operation Humidity |
20% to 85% RH non condensing |
| Storage Humidity |
10%~95% non condensing |
| MTBF |
417K hours |
| Safety |
UL60950-1, CSA C22.2 No 60950-1, TUV EN 60 950-1, IEC 60950-1, EMKO-TSE (74-SEC)207/94 |
| EMC |
EN 55022 CLASS B、FCC CFR 47 PART 15 CLASS B、CNS 13438 CLASS B. |
|
CNS 13438 CLASS B; EN 55024:EN 61000-4-2,3,4,5,6,8. |