| Input Voltage |
88 ~ 264Vac 120 ~ 370Vdc |
| Input Frequency |
47 ~ 63Hz |
| Input Current |
1.6A/115V, 1.0A/230V |
| Inrush Current |
20A/15V, 40A/230V cold start |
| Leakage Current |
<1mA/240Vac |
| Setup, Rise Time |
800ms, 50ms/230Vac 1600ms, 50ms/115Vac at full load |
| Hold Up Time |
80ms/230Vac 16ms/115Vac at full load |
| Over Load Protection |
105%~150% rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Hiccup mode, recovers automatically after fault condition is removed |
| DC Alarm Signal (Optional) |
AC fail CN1 PIN2 |
|
Battery low under charge voltage 82.5% ±2% CN1 PIN1 |
|
Normal 0.8V max.Abnormal 5V ±0.5V |
| Working Temperature |
-10°C ~ +60°C (Refer to output load derating curve) |
| Worhing Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C ~ +85°C, 10% ~ 95% RH |
| Temperature Coefficient |
±0.03% /°C (0~50°C) on 1st output |
| Vibration |
10 ~ 500Hz, 2G 10min./1 cycle, 60min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC, I/P-FG:1.5KVAC, O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| Safety Standards |
UL60950-1, TUV EN60950-1 Approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; ENV50204; |
|
EN61000-4-2,3,4,5,6,8,11; EN55024, Light industry level, criteria A |
| MTBF |
304.3K hrs min. MIL-HDBK-217F (25°C) |