| Input Voltage |
90 ~ 264Vac 127 ~ 370Vdc |
| Input Frequency |
47 ~ 63Hz |
| Input Current |
1.2A at 115Vac (0.9A for 3.3V) 0.8A at 230Vac (0.6A for 3.3V) |
| Inrush Current |
18A at 115Vac 35A at 230Vac, cold start |
| Leakage Current |
<1mA / 240Vac |
| Set Up, Rise Time |
100ms, 40ms/230Vac 100ms, 40ms/115Vac at full load |
| Hold Time |
70ms/230Vac 12ms/115Vac at full load |
| Over Load Protection |
122 ~ 160% rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Hiccup mode, recovers automatically after fault condition is removed |
| Remote On/Off |
RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V power off |
| Working Temperature |
-20°C ~ +70°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C ~ +85°C , 10 ~ 95% RH |
| Temperature Coefficient |
±0.04%/°C (0 ~ 50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| Safety Standards |
UL60950-1, TUV EN60950-1 Approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2 (EN50082-2) Heavy industry level criteria A |
| MTBF |
341.7Khrs min. MIL-HDBK-217F (25°C) |