| Input Voltage |
88V ~ 264Vac or 125V ~ 375VDC Universal full range |
| Input Frequency |
47 ~ 63 Hz |
| Input Current |
<1.3A @ 100Vac input, full load condition |
| Inrush Current |
<30A@115V, <50A@230Vac input, Cold start at 25°C ambient |
| Leakage Current |
<1.5mA @ 264Vac input |
| Rise Time |
<30mS |
| Hold Up Time |
>60mS@230V, full load condition |
| Set Up Time |
<1.2S@115V , <0.6S@230V |
| Green Mode Function |
Power consumption at No load < 0.5W at 240Vac input |
| Over Voltage Protection |
Shutdown, it need re-power on to recover |
| Over Load Protection |
Over 105%~ 150% of rating, recovers automatically after fault condition has been removed |
| Short Circuit Protection |
Shutdown, recovers automatically after fault condition has been removed |
| Operating Temperature |
-20°C ~ +70°C ; De-rating: 45 ~ 70°C: 2.5%/°C |
| Operating Humidity |
20% ~ 85% (non condensing) |
| Storage Temperature, Humidity |
-40°C ~ +85°C; 10% ~ 95% (non condensing) |
| Withstand Voltage |
I/P-O/P:3KVAC, I/P-PE:1.5KVAC, O/P-PE:0.5KVAC, 1minute |
| Safety Standards |
UL60950-1, CSA C22.2 No.60950-1, TUV EN60950-1, IEC60950-1, EMKO-TSE (74-SEC) 207/94 standard |
| EMC |
EN55022 Class B, FCC CFR 47 PART 15 Class B, CNS 13438 Class B, |
|
EN61000-3-2,3 Class A, EN55024 : EN61000-4-2,3,4,5,6,8,11 |
| Cooling |
Natural Cooling |
| MTBF |
335K hours |