General Specifications
| Input voltage |
88 to 264VAC 120 to 370VDC |
| Input Frequency |
47 to 63Hz |
| AC current |
1.6A at 115V, 1.0A at 230V |
| Inrush current |
20A at 115V, 40A at 230V cold start |
| Leakage current |
<1mA/240VAC |
| Setup, Rise time |
800ms, 50ms/230Vac 1300ms, 50ms/115VAC at full load |
| Hold Up Time |
80ms/230VAC 16mc/115VAC at full load |
| Overload protection |
105%~150% @ 230VAC, pulsing hiccup shutdown with autoRecovery. |
| Over voltage protection |
105~135% on 1st output, pulse by pulse |
| DC alarm signal |
AC fail, first output pin2Battery low under charge voltage 82.5%+/-2% 1st output pin1 Normal 0.8V m |
| Vibration |
10~500Hz, 2G 10min./1 cycle, period for 60min. each axes |
| Withstand voltage |
I/P-O/P:3KVAC, I/P-FG:1.5KVAC, O/P-FG:0.5KVAC |
| Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms |
| Working temperature, humidity |
-10°C~+60°C (refer to the derating curve), 20%~90% RH |
| Storage temperature, humidity |
-20°C~+85°C, 10%~95% RH |
| Temperature coefficient |
+/-0.03% / C (0~50°C) on 1st output |
| Safety |
Meets IEC950 requirement (not applied for) |
| EMC standards |
CISPR22 (EN55022) Class B, EN61000-4-2,3,4,5,6,8,11,EN61000-3-2,-3 Verification |
| Dimensions |
159 x 97 x 38mm |
|