| Input voltage |
85~264Vac; 120~370Vdc |
| Input frequency |
47~63Hz |
| Input Current |
2A/115Vac 1A/230Vac |
| Inrush Current |
20A/115V, 40A/230V typically; cold start |
| Leakage Current |
<3.5mA at 240Vac |
| Setup, Rise Time |
300ms, 50ms / 230VAC 800ms, 50ms / 115VAC at full load |
| Hold Up Time |
80ms/230VAC 10ms/115VAC at full load |
| Over Load Protection |
105%~150% rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed. |
| Over Voltage Protection |
5V: 5.75~6.75V |
|
Hiccup mode, recovers automatically after fault condition is removed. |
| Working Temperature |
0°C to +60°C, refer to derating curve |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature |
-20°C ro +85°C |
| Storage Humidity |
10 ~ 95% RH |
| Temperature Coefficient |
±0.03%/°C (0 ~ 50°C) on +5V output |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| Safety Standards |
UL1012, UL60950, TUV EN60950 Approved |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMC |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A |
| MTBF |
301.2K hrs min. MIL-HDBK-217F (25C°) |
| Connection |
7P/9.5mm pitch terminal block |