| Voltage Range |
90 ~ 264Vac 135~370Vdc |
| Input Frequency |
47 ~ 63Hz |
| AC Current |
1.5A / 100Vac |
| Inrush Current (max.) |
40A / 230Vac |
| Leakage Current (max.) |
0.75mA / 240Vac |
| Voltage Adj. Range |
Fixed output by internal VR |
| Line Regulation |
±1.0% |
| Setup, Rise, Hold Time |
1s, 50ms, 16ms at full load |
| Over Load Protection |
110~160% rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
110~140% rated output voltage |
|
Shut down o/p voltage, re-power on to recover |
| Over Temperature Protection |
IC1Tj 135°C |
|
Shut down o/p voltage, recovers automatically after temperature goes down |
| Working Temperature |
0°C ~ +50°C (Refer to output load derating curve) |
| Working Humidity |
20%~90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C ~ +85°C, 10~95% RH |
| Temperature Coefficient |
±0.03% /°C (0~50°C) |
| Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC, I/P-FG:1.5KVAC |
| Isolation Rresistance |
I/P-O/P, IP/FG:100M Ohms / 500VDC |
| Safety Standards |
UL1950, CSA22.2, EN60950-1 Approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; |
|
EN61000-4-2,3,4,5,6,11, ENV50204, Light industry level, criteria A |
| MTBF |
300khrs min. MIL-HDBK-217F(25°C) |
| Plug/Standard type |
3~8V R1B: DIN 5 Pin / 8~48V P2J: 2.1 x 5.5 x 11mm, center positive |
| Cable/Standard type |
3~8V AWM2464 18Awg*4c with shield 4ft / 8~48V 18Awg*2c SPT-1 6ft |