| Input Voltage |
90 ~ 264VAC 127 ~ 370VDC |
| Input Frequency |
47 ~ 63Hz |
| Power Factor |
PF >0.95/230VAC PF >0.98/115VAC at full load typically |
| AC Current |
2A/115VAC 1A/230VAC |
| Inrush Current |
80A/230VAC |
| Leakage Current |
<2mA / 240VAC |
| Setup, Rise Time |
3000ms, 80ms at full load |
| Hold Up Time |
50ms/230VAC 16ms/115VAC at full load typically |
| Over Load Protection |
105 ~ 135% rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Shut down o/p voltage, re-power on to recover |
| Over Temperature Protection |
90°C ±15°C (RTH2) Detect on heatsink of power transistor |
|
Shut down o/p voltage, re-power on to recover |
| Working Temperature |
-20°C ~ + 60°C with cooling fan (Refer to output load derating curve) |
| Working Humidity |
20% ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C ~ +85°C , 10 ~ 95% RH |
| Temp. Coefficient |
±0.05% /°C (0 ~ 50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| Safety Standards |
Design refer to UL60950-1, TUV EN60950-1 |
| Withstand Voltage |
I/P-O/P:4.25KVDC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMC |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,3 |
|
EN61000-4-2,3,4,5,6,8,11, ENV205204 Light industry level, criteria A |
| MTBF |
149.3Khrs min. MIL-HDBK-217F (25°C) |
| Dimensions |
169 x 60.7 x 28.5mm |