Sunpower UKSunpower UK
Sunpower UK Product Search

Advanced Search

Featured Product

Request Information

Clipbook

You haven't added any products to your clip book yet.

Add this product to your ClipBook

BS-EN-ISO 9001:2000 certified BS-EN-ISO 9001:2000 certified
We make every effort to ensure the information provided is accurate however we can not be held responsible for errors. Specifications are subject to change without notice; please ensure you conduct testing to ensure the product is suitable for your intended application.

New Products

300W PFC Single Output Battery Charger

300W PFC Single Output Battery Charger Designed for lead acid batteries featuring 3 stage charging characteristics and the automated...
All New Products

In Development

80W Green Mode Single Output AC-DC Desktop Adapter

80W Green Mode Single Output AC-DC Desktop Adapter Designed for both medical and ITE applications SNP-A08 Series features no load input power of <0.3...
All Products in Development

CLG-100-24 - 96W 24V 4A IP67 Class II Power Supply

CLG-100 Series Product Image - CLG-100-24 - 96W 24V 4A IP67 Class II Power Supply

Features

  • Universal Full Range AC Input
  • IP67 design for indoor or outdoor applications
  • UL1310 class 2 PSU with active PFC function
  • PF>0.98@115VAC; >0.95@230VAC
  • Cooling by free air convection
  • 100% full load burn-in test

Standards

UL2PFCTUVCSUUSCE

Case Details

242 x 68 x 39mm

General Specifications

Input Voltage 90~264VAC
Input Frequency 47 ~ 63Hz
Power Factor PF>0.95/230VAC PF>0.98/115VAC at full load
AC Current 12V : 0.8A/115VAC 0.4A/230VAC
15V : 0.9A/115VAC 0.45A/230VAC
20V ~ 48V : 1.1A/115VAC 0.55A/230VAC
Inrush Current 40A at 230VAC, cold start
Leakage Current 0.5mA/240VAC
Voltage Adjustment Range 0% ~ -15% fixed output (by customer choice)
Current Adjustment Range 3% ~ -25% fixed output (by customer choice)
Voltage Tolerance ±5.0%
Line Regulation ±1.0%
Load Regulation ±2.0%
Setup, Rise Time 1200mS, 80mS/230VAC 1200mS, 80mS/115VAC at full load
Hold Up Time 60mS/230VAC 16mS/115VAC at full load
Over Current Protection 95% ~ 100%
Constant current limiting, recovers automatically once fault condition removed
Over Voltage Protection Shut down output voltage, repower on to recover
Over Temperature Protection 90°C ±10°C (RTH2)
Shut down output voltage, repower on to recover
Working Temperature -30°C to +70°C (refer to derating curve)
Working Humidity 20% ~ 90% RH non-condensing
Storage Temperature, Humidity -40°C to +80°C, 10% ~ 95% RH
Temperature Coefficient ±0.03%/°C (0°C to 50°C)
Vibration 10~500Hz, 2G 10min./1 cycle. period for 60 min. each along X, Y, Z axes
Safety Standards UL1310 Class 2, TUV EN60950-1, CAN/CSA C22.2 No. 223-M91 (except 48V) & IP67 Approved
Withstand Voltage I/P-O/P : 4.25KVAC
Isolation Resistance I/P-O/P : 100MOhms/500VDC
EMC EN55022 (CISPR22) Class B, EN61000-3-2,-3; EN61000-4-2,3,4,5,6,8,11; ENV50204
EN55024, Light industry level, Criteria A compliance
MTBF 301Khrs min. MIL-HDBK-217F (20°C)
Dimensions 222 x 68 x 39mm
Input Connection UL E88265-1, 18AWGx3C; 30cm
Output Connection UL 1185, 18AWGx2C; 30cm

CLG-100-24 Output Data

Voltage Rated Current Current Range Rated Power R&N Eff. OVP
24V 4A 0 ~ 4.0A 96W 150mV 87% 27V ~ 34V