| Input Voltage |
90 ~ 264Vac |
| Input Frequency |
47 ~ 63Hz |
| Power Factor |
PF>0.9/230Vac PF>0.98/115Vac at full load |
| AC Current |
0.8A/115Vac 0.4A/230Vac |
| Inrush Current |
10A/230Vac |
| Leakage Current |
0.5mA/240Vac |
| O/P Current Adjustment Range |
3% ~ -25% Fixed output by customer choice |
| O/P Voltage Tolerance |
±10% |
| O/P Line Regulation |
±4.0% |
| O/P Load Regulation |
±10% |
| Set Up, Rise Time |
1500ms, 100ms/230Vac 3000ms, 100ms/115Vac at full load |
| Over Current Protection |
Constant current limiting, recovers automatically after fault condition is removed |
| Short Circuit Protection |
Hiccup mode, recovers automatically after fault condition is removed. |
| Over Voltage Protection |
Shut down o/p voltage, re-power on to recover |
| Over Temperature Protection |
85°C ±10°C (TSW1) Detect on heatsink of power transistor |
|
Shut down o/p voltage, recovers automatically after temperature goes down |
| Working Temperature |
-30°C to +70°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RHnon-condensing |
| Storage Temperature, Humidity |
-40°C to +80°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.03%/°C (0 ~ 50°C ) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for60min. each along X,Y, Z axes |
| Withstand Voltage |
I/P-O/P:4.25KVDC |
| Isolation Resistance |
I/P-O/P:100M Ohms/500VDC |
| Safety Standards |
UL1310 Class 2, CAN/CSAC22.2 No. 223-M91(except for 48V), IP67 Approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A |
| MTBF |
495.7Khrs min. MIL-HDBK-217F (25°C) |