Sunpower UKSunpower UK
Sunpower UK Product Search

Advanced Search

Featured Product

Request Information

Clipbook

You haven't added any products to your clip book yet.

Add this product to your ClipBook

BS-EN-ISO 9001:2000 certified BS-EN-ISO 9001:2000 certified
We make every effort to ensure the information provided is accurate however we can not be held responsible for errors. Specifications are subject to change without notice; please ensure you conduct testing to ensure the product is suitable for your intended application.

New Products

300W PFC Single Output Battery Charger

300W PFC Single Output Battery Charger Designed for lead acid batteries featuring 3 stage charging characteristics and the automated...
All New Products

In Development

80W Green Mode Single Output AC-DC Desktop Adapter

80W Green Mode Single Output AC-DC Desktop Adapter Designed for both medical and ITE applications SNP-A08 Series features no load input power of <0.3...
All Products in Development

ENH-0840A - 400W 80Plus 1U PC PSU

ENH-0840A Product Image - ENH-0840A - 400W 80Plus 1U PC PSU

Features

  • Universal Input Voltage
  • Active PFC
  • Over power, voltage, current & temperature protections
  • Short circuit protection
  • 80 Plus certified

Standards

CE

Case Details

100 x 245 x 40.5mm

General Specifications

Input Voltage 90 ~ 265Vac
Input Frequency 47 ~ 63Hz
Input Current 5.5A/115Vac; 2.5A/230Vac
Power Factor Correction >0.95 at full load
Inrush Current 50A/115Vac; 100A/230Vac, cold start
Output Power 400W
Overshoot <10% of nominal voltage
Efficiency >80% under 20%, 50% & 100% load; at nominal voltage of 115Vac or 230Vac
Remote On/Off Control LL PS-ON low outputs are enabled
LL high or open outputs are disabled
Over Power Protection At 440W ~ 550W ouputs will shutdown and latch off
Over Voltage Protection Should the unit go into OVP it shall latch off.
Over Current Protection +5V, +12V1, +12V2 & +3.3V have seperate OCP circuits to meet 240VA safety requirements
Short Circuit Protection Short to +3.3V, +5V, +12V or -12V rail; shut down and latch off
Short to +5Vsb; once fault removed auto recover
No Load Operation No damage or hazardous condition cahll occur
Rise Time 0.1 ~ 20mS
Power Good turn on delay time 100 ~ 1000mS
turn off delay time 1mS min.
Rise Time 10mS max.
Hold Up Time 16mS at nominal input
Operating Temperature 0°C to 50°C
Operating Humidity 10 to 85% non-condensing
Storage Temperature, Humidity -20°C to +70°C; 5 to 95% non-condensing
Safety Standards Designed to meet UL1950 & CSA C22.2 No 950
EN60950, Semko, Nemko, Demko, CB & TUV Approved
EMC EN61000-4-2, EN61000-4-4, EN61000-4-5,
EN61000-4-3, EN61000-3-2, EN 55022,
FCC Part 15, Subpart J Class B
MTBF 100,000 hrs, MIL-STD-217D/E

ENP-5140GH Output Data

Voltage Voltage Range Current Range R&N OCP OVP
+3.3V ±5% 0.5 ~ 20.0A 50mV 22 ~ 50A 3.6 ~ 4.5V
+5V ±5% 0.2 ~ 20.0A 50mV 22 ~ 48A 5.5 ~ 6.8V
Maximum combined load of +5V & +3.3V 150W
+12V1 ±5% 0.2 ~ 18.0A 120mV 18 ~ 20A 13 ~ 15V
+12V2 ±5% 0.5 ~ 18.0A 120mV 18 ~ 20A 13 ~ 15V
Maximum combined load of +12V1 & +12V2 30A
+5V Loaded at 20A, +12V min combine 2A
-12V ±10% 0 ~ 0.5A 120mV
+5Vsb ±5% 0 .1~ 3.0A 50mV