| Input voltage |
88~132VAC/ 176~264VAC selected by switch. 249~370VDC |
| Input frequency |
47 ~ 63Hz |
| AC current (typ.) |
4.5A/115VAC 2.5A/230VAC |
| Inrush current |
Cold start 40A |
| Leakage current |
<3.5mA / 240VAC |
| Rated power |
216W |
| Setup, rise time |
200ms, 100ms at full load |
| Hold time |
30ms at full load |
| Overload protection |
105% ~ 135% rated output power |
|
Protection type: Fold back current limiting, recovers automatically after fault condition is removed |
| Over voltage protection |
Protection type: Constant voltage limiting, recovers automatically after fault condition is removed |
| Over temp protection |
RTH5≧85°C Detect on heatsink of Q1, Q2 power transistor |
|
Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed |
| Fan control |
RTH5≧60°C Fan on, ≦50°C Fan off |
| Working temp |
-10~+60°C (refer to output load derating curve) |
| Working humidity |
20 ~ 90% RH non-condensing |
| Storage temp., humidity |
-20 ~+85°C, 10 ~ 95% RH |
| Vibration |
10 ~ 500Hz, 2G 10min./1 cycle, 60 min. each along X, Y, Z axes |
| MTBF |
200.6K hrs min. MIL-HDBK-217F (25°C) |
| Safety standard |
CSA60950-1 (UL3101-1, IEC1010-1, EN61010-1) Approved |
| Withstand voltage |
I/P-O/P:3KVAC, I/P-FG:1.5KVAC, O/P-FG:0.5KVAC |
| Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMI conduction & radiation |
Compliance to EN55022 (CISPR22) class B |
| Harmonic current |
Compliance to EN61000-3-2,-3 |
| EMS immunity |
Compliance to EN61000-4-2,3,4; ENV50204, Light industry level, Criteria A |