Home > Products >Enclosed Power Supplies > ID-30B 30W Dual Output AC-DC Isolated Enclosed Switching > ID-30B
|
Features- AC input range selected by switch
- Protections:Short circuit/Over load
- Cooling by free air convection
- Output is isolated from the others
- 100% full load burn-in test
- Fixed switching frequency at 25KHz I/P-O/P:Rated
- Low cost
- High reliability
Case Details
129*98*38mm (L*W*H)
|
General Specifications
| SETUP, RISE, HOLD TIME |
250ms, 100ms, 20ms at full load |
| VOLTAGE RANGE |
90 ~ 130VAC / 180 ~ 260VAC selected by switch on PCB |
| FREQUENCY RANGE |
47 ~ 63Hz |
| EFFICIENCY(Typ.) |
72% |
| AC CURRENT |
0.8A/110VAC 0.4A/220VAC |
| INRUSH CURRENT(max.) |
25A/110VAC 50A/220VAC |
| OVER LOAD |
105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault cond |
| WORKING TEMP. |
0 ~ +50?C (Refer to output load derating curve) |
| WORKING HUMIDITY |
20 ~ 90% RH RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85?C , 10 ~ 95% |
| TEMP. COEFFICIENT |
?0.05%/?C |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| SAFETY STANDARDS |
Design refer to UL1012 |
| WITHSTAND VOLTAGE |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMI CONDUCTION & RADIATION |
Design refer to FCC Part15 J Conduction Class A |
| MTBF |
597.7K hrs min. MIL-HDBK-217F (25?C) |
|
ID-30B
|
DC Voltage
|
Rated Current
|
Current Range
|
Rated Power
|
Ripple & Noise
|
Voltage ADJ Range
|
Voltage Tolerance
|
Line Regulation
|
Load Regulation
|
|
5V
|
2.2A
|
0.1-2.2A
|
35W
|
100mVp-p
|
4.6-5.5V
|
±2.0%
|
±0.5%
|
±1.5%
|
|
24V
|
1A
|
0.1-1A
|
35W
|
150mVp-p
|
N/A
|
±7.0%
|
±0.5%
|
±6.5%
|
|
 |
| Add this product to your ClipBook |