| Input Voltage |
90~264 VAC, 47~440Hz / 127~370VDC. |
| Power Factor |
PF>0.95/230VAC PF>0.98/115VAC, full load |
| AC Input Current |
3.5A at 115VAC, 60Hz or 1.6A at 230VAC, 60Hz full load. |
| Inrush Current |
<25A at 115VAC or <40A at 230VAC Cold start |
| Setup, Rise Time |
1000ms, 20ms / 230VAC at full load , 3000ms, 20ms / 115VAC at full load |
| Hold-Up Time |
16ms / 230VAC at full load, 16ms / 115VAC at full load |
| Leakage Current |
<180µA at 264VAC for earth leakage |
|
<100µA at 264VAC for patient leakage |
| DC Output ADJ Range |
-5% to +10% rated output, on first output |
| Over Load Protection |
120~160% rated load |
|
Auto recovery once fault condition removed |
| Over Voltage Protection |
115%~135% rated load, on first output |
| Over Temperature Protection |
At 95°C. Will shut down and recover automatically after temperature goes down. |
| Power Good/Fail Signal |
TTL logic high for power good and TTL low for power fail. |
| Remote Control |
RC+/RC-:0 ~ 0.8V=power on; 4 ~ 10V=power off sink current<4~10mA |
| Working Temperature |
-20°C to 70°C (refer to derating curve) |
| Working Humidity |
20~90% RH non-condensing. |
| Storage Temp , Humidity |
-40°C to +85°C, 10~90% RH |
| Temperature Coefficient |
±0.04%/°C (0~50°C) full load |
| Vibration |
2G 10Hz ~500Hz 10 min cycle. |
| Medical Safety Standards |
UL60601-1, TUV EN60601-1 approved |
| Commercial Safety Standards |
Complies with UL60950-1, TUV EN60950-1 |
| Withstand Voltage |
I/P-O/P: 4000VAC I/P-FG, O/P-FG: 1500VAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG : >100M Ohms |
| EMI |
Compliance to EN55011 Class B, EN55022 Class B, EN61000-3-2, EN61000-3-3 |
| EMS |
Compliance to EN61000-4-2 Level 3, 8KV, EN61000-4-2 Level 2, 4KV |
|
EN61000-4-3 Level 2, 3V/m , EN61000-4-3 Level 3, 10V/m, |
|
EN61000-4-4 Level 2, 1KV/5KHz, EN61000-4-4 Level 3, 2KV/5KHz |
|
EN61000-4-5 Level 4, 2KV/Line-Line, 4KV/Line-Earth, |
|
EN61000-4-6 Level 2, 3Vrms/m, Level 3, 10Vrms/m |
|
EN61000-4-8 Level 2, 3A/m, EN61000-4-8 Level 3, 10A/m, EN61000-4-11 Compliance |
|
ENV50204 Level 2, 3V/m, 900MHz, ENV50204 Level 3, 10A/m, 900MHz |
| MTBF |
262,100 hours min MIL-HDBK-217F |