| Input Voltage |
86 to 264Vac or 120 to 370Vdc |
| Input Frequency |
47 to 63Hz |
| Input Current |
6.3A at 115Vac; 3.2A at 230Vac |
| Inrush Current |
25A at 115Vac; 40A at 230Vac, cold start |
| Power Factor Correction |
>0.95 at 230Vac; >0.98 at 115Vac; full load |
| Efficiency |
83% typically |
| Leakage Current |
<1.5mA at 240Vac |
| Output Power |
450W maximum |
| Setup, Rise, Hold-Up Time |
1500ms, 50ms, 20ms at full load |
| Over Load Protection |
Constant Current limiting, recovers automatically once fault condition removed |
| Over Temperature Protection |
Thermal switch detect on the heatsink of power MOSFET |
|
Should the power supply reach excessive temperatures it shall shut down |
|
and auto recover once temperature returns to operable levels |
| Fan Fail |
The outputs shall shut down should the fan malfunction |
| Remote Control |
RC+/RC-: 0 to 0.8V or Short, Power on |
|
RC+/RC-: 4 to 12V or Open, Power Off |
| Remote Inhibit Control |
RC+/RC-:0V~0.8V or OPEN, POWER ON |
|
RC+/RC-:4V~12V or OPEN, POWER OFF |
| Auxiliary Power |
12V at 0.1A (only for remote on/off) |
| Withstand Voltage |
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, 1 minute |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100MW/500Vdc |
| Operating Temperature |
-20°C to +70°C (refer to de-rating curve) |
| Operating Humidity |
20% to 90% RH Non-condensing |
| Storage Temperature, Humidity |
-40°C to +85°C, 10% to 95% RH |
| Temperature Coefficient |
±0.03%/°C (0°C to 50°C) |
| Vibration |
10 to 500Hz, 2G 10min./1 cycle, 60 min. each along X, Y, Z axes |
| Safety Standards |
UL60950-1, TUV EN60950-1, EN60601-1 approved |
| EMC |
Complies to EN55022 Class B, EN6100-3, -2,3, EN61000-4-2,3,4,5,6,8,11, |
|
ENV50204, EN55024, EN61000-6-1, EN61204-3 Light Industrial Level, Criteria A |