| Input Voltage |
85 ~ 264VAC 120 ~ 370VDC |
| Input Frequency |
47 ~ 440Hz |
| AC Current |
0.6A/115VAC 0.4A/230VAC |
| Inrush Current |
30A/115VAC 65A/230VAC typically, cold start |
| Setup, Rise Time |
500ms, 20ms/230VAC 500ms, 20ms/115VAC at full load |
| Holdup Time |
50ms/230VAC 16ms/115VAC typically at full load |
| Overload Protection |
Above 105% rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Protection type Shut off |
| Over Temperature Protection |
Tj 160°C typically (U1) Detect on main control IC |
|
Shut down o/p voltage, recovers automatically after temperature goes down |
| Working Temperature |
-20°C to +65°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-40°C to +85°C, 10 to 95% RH |
| Temp Coefficient |
±0.03%/°C (0 ~ 50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes |
| Satety Standards |
UL60601-1,TUV EN60601-1 Approved |
| Withstand Voltage |
I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMC |
Compliance to EN55011(CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3 |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3 Medical level, criteria A. |
| MTBF |
487.8Khrs min. MIL-HDBK-217F (25°C) |
| Dimensions |
89 x 51 x 19.3mm |