| Input Voltage |
88 ~ 132VAC / 176 ~ 264VAC selected by switch |
| Input Frequency |
47 ~ 63Hz |
| Power Factor |
>0.65 (with PFC series) |
| AC Current |
3A/115VAC, 1.5A/230VAC |
| Inrush Current |
Cold start, 25A/115VAC 50A/230VAC |
| Leakage Currrent |
<1.5mA/240VAC |
| LED Indicators |
Red: Voltage 105%±1% < Green: Voltage 105%±1% > |
| Overload Protection |
90 ~ 110% rated output power |
|
Constant current limiting, recovers automatically after fault is removed |
| Over Voltage Protection |
Hiccup mode, auto recovery upon removal of fault |
| Over Temperature Protection |
RTH2 ≥70°C ±10°C, Detect on RTH2 thermistor |
|
Shut down o/p voltage, recovers automatically after temperature goes down |
| Working Temperature |
-10°C to +45°C, (refer to ouput load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C to +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.05%/°C (0~45°C) |
| Vibration |
10~500Hz, 2G 10min./1cycle,60min. each along X,Y,Z axes |
| Withstand Voltage |
I/P-O/P:3KV, I/P-FG:1.5KV, O/P-FG:0.5KV |
| Isolation Resistance |
I/P-O/P,I/P-FG, O/P-FG:100M Ohms/500VDC |
| Safety Standards |
UL60950-1, TUV EN60950-1, EN60335, EN60335-1, EN60335-2-29 Approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3, |
|
EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,Light industry level, Criteria A |
| MTBF |
149.6K hrs min. MIL-HDBK-217F (25°C) |