S-100-5 - S-100-5
Home > Products >Enclosed Power Supplies > S-100 Series 100W Single Output AC-DC Enclosed Switching Power > S-100-5
|
Features- AC input range selectable by switch
- Protections:Short circuit/Over load
- Cooling by free air convection
- 100% full load burn-in test
- Fixed switching frequency at 25KHz
- Low cost
- High reliability
Case Details
199 x 98 x 38mm
|
General Specifications
| SETUP, RISE, HOLD TIME |
200ms, 80ms, 20ms at full load |
| VOLTAGE RANGE |
85 ~ 132VAC/180 ~ 264VAC selected by switch 255 ~ 370VDC |
| FREQUENCY RANGE |
47 ~ 63Hz |
| AC CURRENT |
2.4A/115VAC 1.2A/230VAC |
| INRUSH CURRENT (max.) |
COLD START 30A/115VAC 60A/230VAC |
| LEAKAGE CURRENT |
<1mA / 240VAC |
| OVER LOAD |
105 ~ 150% rated output power (150 ~ 200% rated output power for S-100-7.5 only) Protection type : S |
| WORKING TEMP. |
-10 ~ +60?C (Refer to output load derating curve) |
| WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85?C , 10 ~ 95% RH |
| TEMP. COEFFICIENT |
?0.03%/?C (0 ~ 50?C) |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| SAFETY STANDARDS |
Design refer to UL1012 |
| WITHSTAND VOLTAGE |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMI CONDUCTION & RADIATION |
Design refer to FCC Part15 J Conduction Class B |
| MTBF |
322.4K hrs min. MIL-HDBK-217F (25?C) |
|
S-100-5
|
DC Voltage
|
Rated Current
|
Current Range
|
Rated Power
|
Ripple & Noise
|
Voltage ADJ Range
|
Voltage Tolerance
|
Line Regulation
|
Load Regulation
|
Efficiency
|
|
5V
|
20A
|
0-20A
|
100W
|
100mVp-p
|
4.75-5.5V
|
±2.0%
|
±0.5%
|
±0.5%
|
78%
|
|
 |
| Add this product to your ClipBook |