General Specifications
| Input Voltage |
88~132Vac/176V~264Vac selectable by switch |
| Input Frequency |
47 ~ 63Hz |
| AC Current |
3.15A/115Vac 1.5A/230Vac |
| Inrush Current |
20A/115Vac 40A/230Vac, cold start |
| Leakage Current |
<1mA/240Vac |
| Setup, Rise, Hold Up Time |
1000mS, 30mS, 20mS at full load |
| Over Load Protection |
105%~150% rated output power |
|
Hiccup mode, auto-recovery |
| Over Voltage Protection |
Hiccup mode and recover automatically once fault removed |
| Working Temperature |
-10°C to 60°C (refer to output derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C to +85°C, 10~95% RH |
| Temperature Coefficient |
±0.03%/°C (0~50°C) |
| Vibration |
10~500Hz, 2G 10min./1 cycle, 60 min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3.0KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
| Safety Standards |
UL1012, UL60950-1,TUV EN60950-1Approved CSA60950-1 (for 24V only |
| EMC Standards |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3, |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A |
| MTBF |
314.9K hours min |
|