S-25-12 - S-25-12
Home > Products >Enclosed Power Supplies > S-25 Series 25W Single Output Switching Power Supply > S-25-12
|
Features- Universal AC input
- Short circuit, over load, over voltage protections
- Cooling by free air convection
- 100% full load burn-in test
- Fixed switching frequency at 56KHz
Standards
 
Case Details
99 x 97 x 36mm
|
General Specifications
| Input Voltage |
85~264Vac 120 ~ 370Vdc |
| Input Frequency |
47-63Hz |
| Input Current |
0.6A/115Vac 0.35A/230Vac |
| Inrush Current |
13A/ 115V 25A/ 230V |
| Leakage Current |
<0.75mA / 240Vac |
| Line Regulation |
±0.5% |
| Set Up, Rise Time |
300ms, 50ms/230Vac 800ms, 50ms/115Vac at full load |
| Hold Time |
90ms/230Vac 12ms/115Vac at full load |
| Over Load Protection |
105%~150% rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Hiccup mode, recovers automatically after fault condition is removed |
| Working Temperature |
-10°C ~ +60°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C ~ +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.03%/°C (0 ~ 50°C ) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| Safety Standards |
UL1012, TUV EN60950-1 Approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3, ENV50204, |
|
EN61000-4-2,3,4,5; EN55024, Light industry level, criteria A |
| MTBF |
330.8K hrs min. MIL-HDBK-217F (25°C) |
|
S-25-12
|
DC Voltage
|
Rated Current
|
Current Range
|
Rated Power
|
Ripple & Noise
|
Voltage ADJ Range
|
Voltage Tolerance
|
Line Regulation
|
Load Regulation
|
Efficiency
|
Over Voltage
|
|
12V
|
2.1A
|
0-2.1A
|
25.2W
|
100mVp-p
|
10.8-13.2V
|
±1.0%
|
±0.5%
|
±0.5%
|
76% / 115VAC
|
13.8V - 16.2V
|
|
(616KB)
|
| Add this product to your ClipBook |