| Input Voltage |
85 ~ 264Vac 120V ~ 370Vdc |
| Input Frequency |
47 ~ 63Hz |
| Input Current |
1.2A/115Vac 0.6A/230Vac |
| Inrush Crrent |
25A/115Vac 50A/230Vac, Cold start |
| Leakage Current |
<1mA/240Vac |
| Set Up, Rise Time |
300ms, 50ms/230Vac 800ms, 50ms/115Vac at full load |
| Hold Time |
70ms/230Vac 15ms/115Vac at full load |
| Over Load Protection |
105%~150% rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Hiccup mode, recovers automatically after fault condition is removed |
| Working Temperature |
-10°C to +60°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-20°C to +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.03%/°C (0 ~ 50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for60min. each along X,Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| Safety Standards |
UL 1012, UL60950-1, TUV EN60950-1 Approved |
| EMC Standards |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3, ENV50204, |
|
EN61000-4-2,3,4,5; EN55024, Light industry level, criteria A |
| MTBF |
314.1K hrs min. MIL-HDBK-217F (25°C) |