SDX-6250-48 - 250W 1U DC Input ATX Power Supply
Home > Products >DC-DC PC Power > SDX-6250-48 250W 1U DC Input ATX Power Supply > 250W 1U DC Input ATX Power Supply
|
Features- DC input 48V
- Input and output isolation
- Soft start function, low inrush current
- Input under and over voltage protection
- Over load, over voltage & short circuit protection
- Built-in long life ball bearing fan
- 100% 50°C burn-in test
- Meet Intel ATX 2.01 / ATX2.03 / ATX 12V / EPS
- UL, cUL, TUV, CB, CE certified
Standards
  
Case Details
100 x 205 x 40.5mm
|
General Specifications
| Input Voltage |
40V ~ 65V DC Typical 48V |
| Input Current |
<9A @ 40V DC input, full load condition |
| Efficiency |
70% |
| Over Load Protection |
Over 105% ~ 150% of rating, shutdown. Auto recovery when fault condition been removed. |
| Over Voltage Protection |
+5V: +5.8V~+7.0V, +12V: +13.8V~+17.5V Shutdown. Auto recovery when fault condition been removed. |
| Short Circuit Protection |
Shutdown. Auto recovery when fault condition been removed. |
| Rise time |
<20mS |
| TTL Signal |
Power Good Signal, PS-ON Signal |
| Cooling |
2 10CFM (min.) DC ball bearing Fan |
| Temperature |
Operating: 0~70°C; derating: 45°C ~70°C : 2.5%/°C. Storage: -10~+75°C |
| Humidity |
Operating: 20% ~ 85%; Storage: 10% ~ 95% (non condensing) |
| M.T.B.F. |
138K hours |
| Safety |
UL 60950, CSA C22.2 No.60950, TUV EN 60950, IEC 60950, EMKO-TSE (74-SEC)207/94 Certified |
| EMC |
FCC CFR 47 PART 15 CLASS B, EN 50081-1, CNS 13438 CALSS B, EN 50082-1 (1997) |
|
Output Data
|
Voltage
|
Min. Load
|
Max. Load
|
Regulation
|
Ripple Noise (max)
|
Efficiency (TYP)
|
Max Power
|
OVP
|
|
+3.3V
|
0.1A
|
20A
|
±5%
|
50mV
|
70%
|
140W
|
+3.8V~+4.6V
|
|
+5V
|
2A
|
28A
|
±5%
|
50mV
|
70%
|
140W
|
+5.8V~+7.0V
|
|
+12V
|
0.2A
|
16A
|
±5%
|
120mV
|
70%
|
250W
|
+13.8V~+17.5V
|
|
-5V
|
0A
|
0.5A
|
±5%
|
50mV
|
70%
|
250W
|
|
|
-12V
|
0A
|
1A
|
+8/-5%
|
200mV
|
70%
|
250W
|
|
|
+5Vsb
|
0A
|
2A
|
±5%
|
50mV
|
70%
|
250W
|
|
|
 |