| Input Voltage |
88 to 264Vac 120 to 370Vdc |
| Input Frequency |
47 to 63Hz |
| Power Factor |
PF>0.95/230Vac PF>0.98/115Vac at full load |
| Input Current |
5A/115Vac (2.5A for 3.3V); 2.5A/230Vac (1.5A for 3.3V) |
| Inrush Current |
20A/115Vac 40A/230Vac |
| Leakage Current |
<1mA / 240Vac |
| Setup, Rise Time |
800ms, 50ms/230Vac 2500ms, 50ms/115Vac at full load |
| Hold Up Time |
16ms/230Vac 16ms/115Vac at full load |
| Over Load Protection |
105 to 135% rated output power |
|
Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Shut down o/p voltage, re-power on to recover |
| Over Temperature Protection |
80°C ±5°C (70°C ±5°C 3.3V,5V only) (TSW1 : Detect on heatsink of power transistor) |
|
Shun down o/p voltage, recovers automatically after temperature goes down |
| Working Temperature |
-20°C to +65°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
40°C to +85°C, 10~95% RH |
| Temperature Coefficient |
±0.03%/°C (0~50°C) |
| Vibration |
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| Safety Standards |
UL60950-1, TUV EN60950-1 Approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204 Light industry level, criteria A |
| MTBF |
207K hrs min. MIL-HDBK-217F (25°C) |