SE-1000 Series - 1000W Single Output Industrial Power Supply
Home > Products >Enclosed Power Supplies > 1000W Single Output Industrial Power Supply
Features- AC input active surge current limiting
- AC input range selected by switch
- Short circuit, over load, over voltage & over temperature protection
- Forced air cooling by built-in DC ball bearing fan
- High power density 7.3w/in³
- DC OK signal output
- Built-in remote ON-OFF control
- Built-in remote sense function
- UL approved
- Non RoHS Product
Applications- General electronic applications
- Factory automation
- Moving sign industry
DescriptionSE-1000 Series are 1000W enclosed type switching power supplies designed for the growing demand of low cost high wattage applications. Featuring 7.3W/in³ of high power density and the built-in DC ball bearing fan SE-1000 can provide full output wattage up to 50°C of ambient temperature. Along with the standard features of remote on/off control, remote sense function and DC ok signal output SE-1000 tries to offer you an economical alternative with the most application flexibility.
|
Standards
|
Case Details
278 x 127 x 63.5mm
|
Specification
| Input Voltage Range |
90 ~ 132VAC / 180 ~ 264VAC selected by TB2 254 ~ 370VDC |
| Input Frequency |
47 ~ 63Hz |
| AC Current |
17.5A/115VAC 10A/230VAC typically |
| Inrush Current |
35A/115VAC 55A/230VAC typically |
| Leakage Current |
<2.5mA / 240VAC |
| Setup, Rise Time |
300ms, 50ms/230VAC 300ms, 50ms/115VAC at full load |
| Hold Time |
20ms/230VAC 15ms/115VAC at full load |
| Over Load Protection |
105~125% rated output power. |
|
Shutdown o/p voltage, re-power on to recover |
| Over Voltage Protection |
Shutdown o/p voltage, re-power on to recover |
| Over Temperature Protection |
70°C±5°C (TSW1) Detect on heatsink of power transistor |
|
Shutdown o/p voltage, recovers automatically after temperature goes down. |
| DC_OK Signal |
PSU turn on: 3.3V ~ 5.6V PUS turn off: 0 ~ 1V |
| Remote Control |
RC+/RC-: 0 ~ 0.8V power on; 4 ~ 10V power off |
| Working Temperatire |
-20 °C ~+60°C (refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temp., Humidity |
-40 ~+85°C, 10 ~ 95% RH |
| Temp. Coefficient |
±0.05%/°C (0~50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1 cycle, 60 min. each along X,Y,Z axes |
| Safety Standards |
UL60950-1 approved |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| MTBF |
251.6K hrs mins. MIL-HDBK-217F (25°C) |
|
Items
SE-1000 Series Output Data
|
Part Code
|
Voltage
|
Rated Current
|
Current Range
|
Rated Power
|
R&N
|
Volt adj.
|
Tol.
|
Line Reg.
|
Load Reg.
|
Eff.
|
OVP
|
|
SE-1000-5
|
5V
|
150A
|
0~150A
|
750W
|
150mV
|
3.3~5.5V
|
±1.0%
|
±0.5%
|
±1.0%
|
80%
|
5.75 ~ 6.3V
|
|
SE-1000-9
|
9V
|
100A
|
0~100A
|
900W
|
150mV
|
7.5~10V
|
±1.0%
|
±0.5%
|
±0.5%
|
84%
|
10.4 ~ 12.2V
|
|
SE-1000-12
|
12V
|
83.3A
|
0~83.3A
|
999.6W
|
150mV
|
10~13.5V
|
±1.0%
|
±0.5%
|
±0.5%
|
84%
|
13.8 ~ 16.2V
|
|
SE-1000-15
|
15V
|
66.7A
|
0~66.7A
|
1000.5W
|
150mV
|
13.5~16.5V
|
±1.0%
|
±0.5%
|
±0.5%
|
86%
|
18 ~ 21V
|
|
SE-1000-24
|
24V
|
41.7A
|
0~41.7A
|
1000.8W
|
200mV
|
22~27.5V
|
±1.0%
|
±0.5%
|
±0.5%
|
88%
|
28 ~ 32.4V
|
|
SE-1000-48
|
48V
|
20.8V
|
0~20.8A
|
998.4W
|
200mV
|
43~56V
|
±1.0%
|
±0.5%
|
±0.5%
|
89%
|
57.6 ~ 67.2V
|
|