Sunpower UKSunpower UK
Sunpower UK Product Search

Advanced Search

Featured Product

Request Information

Clipbook

You haven't added any products to your clip book yet.

BS-EN-ISO 9001:2000 certified BS-EN-ISO 9001:2000 certified
We make every effort to ensure the information provided is accurate however we can not be held responsible for errors. Specifications are subject to change without notice; please ensure you conduct testing to ensure the product is suitable for your intended application.

New Products

300W PFC Single Output Battery Charger

300W PFC Single Output Battery Charger Designed for lead acid batteries featuring 3 stage charging characteristics and the automated...
All New Products

In Development

80W Green Mode Single Output AC-DC Desktop Adapter

80W Green Mode Single Output AC-DC Desktop Adapter Designed for both medical and ITE applications SNP-A08 Series features no load input power of <0.3...
All Products in Development

SDU-100BD Series - 100W Dual Output U-Bracket DC-DC Converter

Features

  • Low inrush current, soft start function
  • Input & output isolation
  • Input polarity reverse protection
  • Input under / over voltage protection
  • Over load, over voltage & short circuit protection
  • FR4 glass epoxy double side circuit board, meet UL-94V0
  • 100% 50° burn-in test
  • UL, cUL certified (SDU-100BD1), Meet TUV, CB, CE standard

Standards

CETUVULRULRC
Product Image - SDU-100BD Series - 100W Dual Output U-Bracket DC-DC Converter

Case Details

133.5 x 84 x 38 mm

Specification

Input Voltage DC 18V ~ 56V
Input Current 8A max at 18V DC input, full load condition
Efficiency 72%
Max Power Natural cooling: 80W; forced air cooling: 100W
Input Protection Fuse, 12A/125V
Over Load Protection Over 115% ~ 180% of rating, recovers automatically after fault condition has been removed.
Over Voltage Protection Shut down when V1 over +5.8 ~ 7.0V. Recovers automatically after fault condition has been removed.
Short Circuit Protection Shutdown, recovers automatically after fault condition has been removed.
Rise Time <20mS
Cooling Natural Cooling; when output exceed 80W a 16CFM (min.) DC fan is required.
Temperature Operating: 0~70?C; derating: 45?C ~70?C : 2.5%/?C. Storage: -40~+85?C
Humidity Operating: 20% ~ 85%; Storage: 10% ~ 95% (non condensing)
M.T.B.F. SDU-100BD1: 275K hours. SDU-100DB2: 270K hours
Safety Meet UL 60950, CSA C22.2 No.60950, TUV EN 60950, IEC 60950, EMKO-TSE (74-SEC)207/94
EMI FCC CFR 47 PART 15 CLASS B, EN 50081-1, CNS 13438 CLASS B.
EMS EN 50082-1 (1997)

Items

SDU-100BD Series

Part No Voltage Min Load Max Load Regulation Ripple Noise (MAX) Efficiency (TYP) Max. Power
SDU-100BD1 +5V 2A 16A ±3% 50mV 72% Natural Cooling: 80W; forced air cooling :100W
+12V 0A 2.2A +2% ~ -6% 80mV 72% Natural Cooling: 80W; forced air cooling :100W
SDU-100BD2 +5V 2A 16A ±3% 50mV 72% Natural Cooling: 80W; forced air cooling :100W
+24V 0A 1.5A +2%~ -6% 120mV 72% Natural Cooling: 80W; forced air cooling :100W
Download PDF document

 

 
© Copyright 2008 Sunpower UK : Website design, hosting & Technology: Strategies Group Plc