Sunpower UKSunpower UK
Sunpower UK Product Search

Advanced Search

Featured Product

Request Information

Clipbook

You haven't added any products to your clip book yet.

BS-EN-ISO 9001:2000 certified BS-EN-ISO 9001:2000 certified
We make every effort to ensure the information provided is accurate however we can not be held responsible for errors. Specifications are subject to change without notice; please ensure you conduct testing to ensure the product is suitable for your intended application.

New Products

300W PFC Single Output Battery Charger

300W PFC Single Output Battery Charger Designed for lead acid batteries featuring 3 stage charging characteristics and the automated...
All New Products

In Development

80W Green Mode Single Output AC-DC Desktop Adapter

80W Green Mode Single Output AC-DC Desktop Adapter Designed for both medical and ITE applications SNP-A08 Series features no load input power of <0.3...
All Products in Development

PPT-125 Series - 125W Triple Output PFC Function Open Frame Power S

Features

  • Universal AC input / Full range
  • Built-in active PFC function
  • Protections:Short circuit/Over load/Over voltage
  • PWM control and regulated
  • High power density 6.117W/inch
  • Built-in remote sense function
  • LED indicator for power on
  • 100% full load burn-in test
  • 125W with 18CFM forced air

Standards

CBCECSUUSPFCTUV
Product Image - PPT-125 Series - 125W Triple Output PFC Function Open Frame Power S

Case Details

127 x 76.2 x 34.6mm

Specification

INPUT VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC
INPUT FREQUENCY RANGE 47~63Hz
POWER FACTOR PF>0.93/230VAC PF>0.98/115VAC at full load
AC CURRENT 1.7A/115VAC 0.75A/230VAC
INRUSH CURRENT (max.) COLD START 40A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
PROTECTION OVER LOAD 130 ~ 160% rated output powerProtection type : Fold back current limiting, recovers automatically
PROTECTION OVER VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP., HUMIDITY -20 ~ +60°C (Refer to output load derating curve)
WORKING TEMP. 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85°C , 10 ~ 95% RH
TEMP. COEFFICIENT ?0.05%/ (0 ~ 50°C)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS UL60950-1, TUV EN60950-1 Approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
MTBF 94.7Khrs min. MIL-HDBK-217F (25°C)

Items

PPT-125 Series

PART NO VOLTAGE RATED CURRENT CURRENT RANGE (convection) CURRENT RANGE (18CFM FAN) RATED POWER (convection) RATED POWER (18CFM FAN) R&N VOLTAGE ADJ. RANGE TOL LINE REG LOAD REG EFF OVP
12V 0.5A 0.05 ~ 0.5A 0.05 ~ 0.63A 79W 98.8W 120mV ±6.0% ±0.5% ±5.0% 75%
PPT-125A 3.3V 10A 1 ~ 10A 1 ~ 12.5A 79W 98.8W 100mV 3.13 ~ 3.46V ±3.0% ±0.5% ±3.0% 75% 3.6 ~ 4.45V
5V 8A 0.8 ~ 8A 0.8 ~ 10A 79W 98.8W 100mV ±5.0% ±0.5% ±3.0% 75%
PPT-125B 5V 11.5A 1 ~ 11.5A 1 ~ 14.38A 99.5W 124.46W 100mV 4.75 ~ 5.25V ±3.0% ±0.5% ±3.0% 78% 5.75 ~ 6.75V
12V 3A 0.3 ~ 3A 0.3 ~ 3.75A 99.5W 124.46W 120mV ±5.0% ±0.5% ±3.0% 78%
-12V 0.5A 0.05 ~ 0.5A 0.05 ~ 0.63A 99.5W 124.46W 120mV ±6.0% ±0.5% ±5.0% 78%
PPT-125C 5V 11A 1 ~ 11A 1 ~ 13.75A 100W 125.15W 100mV 4.75 ~ 5.25V ±3.0% ±0.5% ±3.0% 78% 5.75 ~ 6.75V
15V 2.5A 0.25 ~ 2.5A 0.25 ~ 3.13A 100W 125.15W 150mV ±5.0% ±0.5% ±3.0% 78%
-15V 0.5A 0.05 ~ 0.5A 0.05 ~ 0.63A 100W 125.15W 150mV ±6.0% ±0.5% ±5.0% 78%
PPT-125D 5V 7A 1 ~ 7A 1 ~ 8.75A 101W 126.43W 100mV 4.75 ~ 5.25V ±3.0% ±0.5% ±3.0% 78% 5.75 ~ 6.75V
24V 2.5A 0.25 ~ 2.5A 0.25 ~ 3.13A 101W 126.43W 240mV ±5.0% ±0.5% ±3.0% 78%
12V 0.5A 0.05 ~ 0.5A 0.05 ~ 0.63A 101W 126.43W 120mV ±6.0% ±0.5% ±5.0% 78%