DR-30 Series - 30W Single Output DIN Rail Power Supply
Home > Products >Din Rail > 30W Single Output DIN Rail Power Supply
Features- Universal AC input/Full range
- Short circuit/Over Load/Over voltage protection
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- Isolation Class II
- LED indicator for power on
- 100% full load burn-in test
Applications- Power distribution boxes
- Control cabinet
- Building automation
- Household appliance control
Description30W single output Class II DIN rail switching power supply for the fast growing demand of the DIN rail segment. With Class II protection levels, this series provides users with a safer operating environment and featuring up to 86% efficiency, this series can be cooled by free air convection to significantly increase the reliability and lifetime of the power supply. Also complies with the safety and EMC requirements of EN50178.
|
Standards
  
|
Case Details
78 x 93 x 56mm
|
Specification
| Input Voltage |
85 ~ 264VAC 120 ~ 370VDC |
| Input Frequency |
47 ~ 63Hz |
| AC Current |
0.88A/115VAC 0.48A/230VAC |
| Inrush Current |
15A/115VAC 30A/230VAC cold start |
| Setup, Rise Time |
100ms, 30ms/230VAC 100ms, 30ms/115VAC at full load |
| Hold Time |
100ms/230VAC 21ms/115VAC at full load |
| Over Load Protection |
105 ~ 160% rated output power |
|
Constant current limiting, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Shut down o/p voltage, re-power on to recover |
| Working Temperature |
-20°C to +60°C (Refer to output load derating curve) |
| Working Humidity |
20% to 90% RH non-condensing |
| Storage Temp., Humidity |
-40°C to +85°C , 10% to 95%RH |
| Temp. Coefficient |
±0.03%/°C (0 to 50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| Safety Standards |
UL60950-1, TUV EN60950-1 Approved, Design refer to EN50178 |
| Withstand Voltage |
I/P-O/P:3KVAC |
| Isolation Resistance |
I/P-O/P:100M Ohms/500VDC |
| EMC |
Compliance to EN55011,EN55022 (CISPR22) Class B, EN61000-3-2,-3 |
|
EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-1, EN61204-3 Light industry, Criteria A |
| MTBF |
441.5K hrs min. MIL-HDBK-217F (25°C) |
|
Items
DR-30 Series Output Data
|
Part No
|
Voltage
|
Current
|
Rated Pwr
|
R&N (max)
|
Volt. Adj.
|
Tol.
|
Line Reg.
|
Load Reg.
|
Eff. (typ)
|
OVP
|
|
DR-30-5
|
5V
|
0 ~ 3A
|
15W
|
80mV
|
4.75 ~ 5.5V
|
±2.0%
|
±1.0%
|
±1.0%
|
74%
|
5.75 ~ 6.75V
|
|
DR-30-12
|
12V
|
0 ~ 2A
|
24W
|
120mV
|
10.8 ~ 13.2V
|
±1.0%
|
±1.0%
|
±1.0%
|
81%
|
13.8 ~ 16.2V
|
|
DR-30-15
|
15V
|
0 ~ 2A
|
30W
|
120mV
|
13.5 ~ 16.5V
|
±1.0%
|
±1.0%
|
±1.0%
|
82%
|
17.25 ~ 20.25V
|
|
DR-30-24
|
24V
|
0 ~ 1.5A
|
36W
|
150mV
|
21.6 ~ 26.4V
|
±1.0%
|
±1.0%
|
±1.0%
|
83%
|
27.6 ~ 32.4V
|
|
(292KB)
|