| Input Voltage |
90 ~ 264Vac 127 ~ 370Vdc |
| Input Frequency |
47 ~ 63Hz |
| Power Factor |
0.95/230Vac 0.98/100Vac at full load |
| Input Current |
7A/115Vac 3.5A/230Vac |
| Inrush Current |
20A/115Vac 40A/230Vac |
| Leakage Current |
<1mA/ 240Vac |
| Set Up, Rise Time |
1500ms, 50ms at full load |
| Hold Up Time |
24ms at full load |
| Over Load Protection |
110 ~ 125% rated output power |
|
Constant current limiting, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Shut down o/p voltage, re-power on to recover |
| Over Temperature Protection |
RTH2>95°C detect on heatsink of Q1,Q7 power transistor & L3 output choke |
|
Shut down o/p voltage, recovers automatically after temperature goes down |
| Remote Control |
RC+/RC-: 0 ~ 0.8V=power on ; 4 ~ 10V=power off sink current <4 ~ 10mA |
| Working Temperature |
-10°C ~ +60°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH with 30CFM forced air non-condensing |
| Storage Temperature, Humidity |
-20°C ~ +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.03%/°C (0 ~ 50°C) |
| Vibration |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| Safety Standards |
UL60950-1, TUV EN60950-1 approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; ENV50204; |
|
EN61000-4-2,3,4,5,6,8,11; EN55024, light industry level, criteria A |
| MTBF |
130.1K hrs min. MIL-HDBK-217F (25°C) |