AD-55 Series - 55W Single Output With Battery Charger
Home > Products >Enclosed > 55W Single Output With Battery Charger
Features- International AC input range
- High Efficiency
- Low working temperature
- Soft start circuit
- Limiting AC surge current
- Short circuit, overload & over voltage protected
- 100% full load burn in test
- Built in EMI filter
|
Standards
  
|
Case Details
159 x 97 x 38mm
|
Specification
| Input voltage |
88 to 264VAC 120 to 370VDC |
| Input Frequency |
47 to 63Hz |
| AC current |
1.6A at 115V, 1.0A at 230V |
| Inrush current |
20A at 115V, 40A at 230V cold start |
| Leakage current |
<1mA/240VAC |
| Setup, Rise time |
800ms, 50ms/230Vac 1300ms, 50ms/115VAC at full load |
| Hold Up Time |
80ms/230VAC 16mc/115VAC at full load |
| Overload protection |
105%~150% @ 230VAC, pulsing hiccup shutdown with autoRecovery. |
| Over voltage protection |
105~135% on 1st output, pulse by pulse |
| DC alarm signal |
AC fail, first output pin2Battery low under charge voltage 82.5%+/-2% 1st output pin1 Normal 0.8V m |
| Vibration |
10~500Hz, 2G 10min./1 cycle, period for 60min. each axes |
| Withstand voltage |
I/P-O/P:3KVAC, I/P-FG:1.5KVAC, O/P-FG:0.5KVAC |
| Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms |
| Working temperature, humidity |
-10°C~+60°C (refer to the derating curve), 20%~90% RH |
| Storage temperature, humidity |
-20°C~+85°C, 10%~95% RH |
| Temperature coefficient |
+/-0.03% / C (0~50°C) on 1st output |
| Safety |
Meets IEC950 requirement (not applied for) |
| EMC standards |
CISPR22 (EN55022) Class B, EN61000-4-2,3,4,5,6,8,11,EN61000-3-2,-3 Verification |
| Dimensions |
159 x 97 x 38mm |
|
Items
Output Data
|
Part No
|
Voltage
|
Current
|
Rated Power
|
R&N
|
Volt.Adj. Range
|
Tol.
|
Line Reg.
|
Load Reg.
|
Eff.
|
|
AD-55A
|
13.8V
|
3.5A
|
51.38W
|
100mV
|
12~14.5V
|
±1%
|
±0.5%
|
±0.5%
|
71%
|
|
|
13.4V
|
0.23A
|
|
|
|
|
|
|
|
|
AD-55B
|
27.6V
|
1.8A
|
53.92W
|
100mV
|
24~29V
|
±1%
|
±0.5%
|
±0.5%
|
74%
|
|
|
26.5
|
0.16A
|
|
|
|
|
|
|
|
|
 |
 |
|