Sunpower UKSunpower UK
Sunpower UK Product Search

Advanced Search

Featured Product

Request Information

Clipbook

You haven't added any products to your clip book yet.

BS-EN-ISO 9001:2000 certified BS-EN-ISO 9001:2000 certified
We make every effort to ensure the information provided is accurate however we can not be held responsible for errors. Specifications are subject to change without notice; please ensure you conduct testing to ensure the product is suitable for your intended application.

New Products

300W PFC Single Output Battery Charger

300W PFC Single Output Battery Charger Designed for lead acid batteries featuring 3 stage charging characteristics and the automated...
All New Products

In Development

80W Green Mode Single Output AC-DC Desktop Adapter

80W Green Mode Single Output AC-DC Desktop Adapter Designed for both medical and ITE applications SNP-A08 Series features no load input power of <0.3...
All Products in Development

RPT-60 Series - 60W Triple Output Open Frame Medical PSU

Features

  • Suitable for IT and Medical applications
  • Universal AC input/Full range
  • Low leakage current<200uA
  • Short circuit/Over load/Over voltage protection
  • Cooling by free air convection
  • UL60601-1/IEC60601-1/EN60601-1 medical safety approved
  • Fixed switch frequency at 100KHz

Applications

  • Non-patient connect medical
  • General electronic
  • Low profile IT equipment

Description

Developed for medical and IT applications with the requirement of reduced profiles and complying with both medical and industrial agency standards these units can deliver their fully rated output of 50 to 60W with only free air convection and also have 10% more peak load capability than their larger rivals. Featuring only 200uA of leakage current at 264Vac they can be installed into non-patient contact medical equipment and still comply with Class B EMI regulations. The reduced height of 29mm also makes the unit suitable for 1U applications or other height constraint applications.

Standards

TUVMedicalMEDICALCBCSUUSCE
RPS-60 Series Product Image - RPT-60 Series - 60W Triple Output Open Frame Medical PSU

Case Details

101.6 x 50.8 x 29mm

Specification

Input Voltage 90 to 264Vac 127 to 370Vdc
Input Frequency 47 to 63Hz
AC Current 1.1A at 115Vac 0.7A at 230Vac
Inrush Current 60A at 230Vac 30A at 115Vac cold start
Leakage Current <200uA at 264Vac
Setup, Rise Time 200mS, mS at 230Vac
200mS, 15mS at 115Vac full load
Hold Up Time 70mS at 230Vac, 14mS at 115Vac full load
Overload Protection 115 to 150% rated output power
Hiccup mode, recovers automatically after fault condition is removed
Over Voltage Protection Shut down o/p voltage, re-power on to recover
Working Temperature -20°C to +65°C (Refer to output load derating curve)
Working Humidity 20 to 90% RH non-condensing
Storage Temperature, Humidity -40°C to +85°C, 10 to 95% RH
Temp. Coefficient ±0.03%/°C (0 ~ 45°C)
Vibration 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Safety Standards UL60601-1, TUV EN60601-1 Approved
Withstand Voltage I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3 Medical level, criteria A
MTBF 677.8Khrs min. MIL-HDBK-217F (25°C)

Items

RPT-60 Series Output Data

Part Code Output Voltage Rated Current Current Range Rated Power Peak Load
RPT-60A 5V 4A 0.5~4.4A 46.5W 51.15W (10sec)
12V 2A 0.1~2.2A
-5V 0.5A 0.1~0.55A
RPT-60B 5V 4A 0.5~4.4A 50W 55W (10sec)
12V 2A 0.1~2.2A
-12V 0.5A 0.1~0.55A
RPT-60C 5V 4A 0.5~4.4A 50W 55W (10sec)
15V 1.5A 0.1~1.65A
-15V 0.5A 0.1~0.55A
RPT-60D 5V 3.5A 0.5~3.85A 47.5W 52.25W (10sec)
24V 1A 0.1~1.1A
12V 0.5A 0.1~0.55A
RPT-6003 3.3V 5A 0.5~5.5A 39.9W 43.9W (10sec)
5V 3A 0.3~3.3A
12V 0.7A 0.1~0.77A

RPT-60 Series Output Data

Part Code R&N Tol. Line Reg. Load Reg. Eff. OVP
RPT-60A 80mV +3, -2% ±0.5% ±1.5% 77% 5.75~6.75V
80mV ±6.0% ±1.0% ±2.0%
80mV +9, -8% ±1.0% +5, -7%
RPT-60B 80mV +3, -2% ±0.5% ±1.5% 78% 5.75~6.75V
80mV ±6.0% ±1.0% ±2.0%
100mV +6, -10% ±2.0% ±5.0%
RPT-60C 80mV +3, -2% ±0.5% ±1.5% 79% 5.75~6.75V
100mV ±6.0% ±2.0% ±3.0%
150mV ±8.0% ±2.0% ±4.0%
RPT-60D 80mV +3, -2% ±0.5% ±1.5% 79% 5.75~6.75V
150mV ±6.0% ±2.0% ±3.0%
80mV ±8.0% ±2.0% ±4.0%
RPT-6003 80mV +3, -2% ±0.5% ±1.5% 75% 3.8~4.45V
80mV ±8.0% ±1.0% ±2.0%
80mV ±8.0% ±2.0% +5.5, -5%
Download PDF document  (643KB)

 

 
© Copyright 2008 Sunpower UK : Website design, hosting & Technology: Strategies Group Plc