T-60 Series - 60W Triple Output Switching Power Supply
Home > Products >Enclosed Power Supplies > 60W Triple Output Switching Power Supply
Features- High efficiency, high reliability
- Built in EMI filter, low ripple noise
- 100% full load burn-in test
- Short circuit/ over load/ over voltage protected
- Universal AC input
- Approvals: UL/ TUV/ CE
|
Standards
  
|
Case Details
159 x 97 x 38mm
|
Specification
| Input voltage |
85 ~ 264VAC; 120~370VDC |
| Input frequency |
47-63Hz |
| Inrush current |
Cold start, 25A/ 115V, 50A/ 230V |
| Output voltage |
CH1:+10, -5% ADJ. |
| Overload protection |
105%~150% output pulsing mode |
| Over voltage protection |
CH1 : 115%~135% of output voltage |
| Setup, rise, hold up time |
00ms, 50ms, 10ms/ 115VAC
300ms, 50ms, 80ms/ 230VAC |
| Withstand voltage |
I/P-O/P:3KV, I/P-FG:1.5KV, 1min. |
| Working temperature |
0?C-45?C@100%,-10 ? C@80%,
60?C@60% |
| Safety standard |
UL 1012, TUV EN 60950 |
| EMC standard |
EN55022 class B, IEC801-2,3,4,5,
EN60555-2,3 |
| Connection |
7P/ 9.5mm pitch terminal block |
|
Items
T-60 Series
|
Part No
|
Output
|
Tol.
|
R&N
|
Eff.
|
|
T-60A
|
5V, 0.5-7A
|
±2%
|
100mV
|
72%
|
|
|
12V, 0.2-3.5A
|
±6%
|
100mV
|
72%
|
|
T-60B
|
5V, 0.5-7A
|
±2%
|
100mV
|
72%
|
|
|
12V, 0.2-3.5A
|
±6%
|
100mV
|
72%
|
|
|
-12V, 0-1A
|
±6%
|
100mV
|
72%
|
|
T-60C
|
5V, 0.5-7A
|
±2%
|
100mV
|
72%
|
|
|
15V, 0.2-3A
|
±6%
|
100mV
|
72%
|
|
|
-15V, 0-1A
|
±6%
|
100mV
|
72%
|
|
 |
 |
|