RS-75 Series - 75W Single Output AC-DC Switching Power Supply
Home > Products >Enclosed > 75W Single Output AC-DC Switching Power Supply
Features- Universal AC input / Full range
- Short circuit, over load, over voltage protections
- Cooling by free air convection
- LED indicator for power on
- 100% full load burn-in test
- All using 105°C long life electrolytic capacitors
- Withstand 300VAC surge input for 5 second
- High operating temperature up to 70°C
- Withstand 5G vibration test
- High efficiency, long life and high reliability
|
Standards
  
|
Case Details
129 x 97 x 38mm
|
Specification
| Input Voltage |
88 ~ 264Vac 125 ~ 373Vdc (Withstand 300Vac surge for 5sec. Without damage) |
| Input Frequency |
47 ~ 63Hz |
| Input Current |
2A/115Vac 1.2A/230Vac |
| Inrush Current |
40A/230Vac cold start |
| Leakage Current |
<2mA / 240Vac |
| Set Up, Rise Time |
500ms, 30ms/230Vac 1200ms, 30ms/115Vac at full load |
| Hold Time |
60mS/230Vac 14mS/115Vac at full load |
| Over Load Protection |
110 ~ 150% rated output power |
|
Hiccup mode, recovers automatically after Fault condition is removed |
| Over Voltage Protection |
Hiccup mode, recovers automatically after fault condition is removed |
| Working Temperature |
-25°C ~ +70°C (Refer to output load derating curve) |
| Working Humidity |
20 ~ 90% RH non-condensing |
| Storage Temperature, Humidity |
-40°C ~ +85°C, 10 ~ 95% RH |
| Temperature Coefficient |
±0.03%/°C (0~50°C) |
| Vibration |
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| Safety Standards |
UL60950-1, TUV EN60950-1 Approved |
| EMC |
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; |
|
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) Heavy Industry Level, Criteria A |
| MTBF |
265Khrs min. MIL-HDBK-217F (25°C) |
|
Items
RS-75 Series Output Data
|
Part No
|
Voltage
|
Rated Current
|
Current Range
|
Rated Pwr
|
R&N (max)
|
Volt. Adj.
|
Tol.
|
Line Reg.
|
Load Reg.
|
Eff.
|
OVP
|
|
RS-75-3-3
|
3.3V
|
15A
|
0 ~ 15A
|
49.5W
|
80mV
|
3V ~ 3.6V
|
±3.0%
|
±0.5%
|
±2.0%
|
71%
|
3.8 ~ 4.45V
|
|
RS-75-5
|
5V
|
12A
|
0 ~ 12A
|
60W
|
80mV
|
4.75 ~ 5.5V
|
±2.0%
|
±0.5%
|
±1.0%
|
76%
|
5.75 ~ 6.75V
|
|
RS-75-12
|
12V
|
6A
|
0 ~ 6A
|
72W
|
120mV
|
10.8 ~ 13.2V
|
±1.0%
|
±0.5%
|
±0.5%
|
81%
|
13.8 ~ 16.2V
|
|
RS-75-15
|
15V
|
5A
|
0 ~ 5A
|
75W
|
120mV
|
13.5 ~ 16.5V
|
±1.0%
|
±0.5%
|
±0.5%
|
82%
|
17.25 ~ 20.25V
|
|
RS-75-24
|
24V
|
3.2A
|
0 ~ 3.2A
|
76.8W
|
120mV
|
22 ~ 27.6V
|
±1.0%
|
±0.5%
|
±0.5%
|
85%
|
27.6 ~ 32.4V
|
|
RS-75-48
|
48V
|
1.6A
|
0 ~ 1.6A
|
76.8W
|
200mV
|
42 ~ 54V
|
±1.0%
|
±0.5%
|
±0.5%
|
86%
|
55.2 ~ 64.8V
|
|
(426KB)
|