Features
  • True sine wave output (THD<3%)
  • High surge power up to 2000W
  • High efficiency up to 92%
  • Power ON-OFF switch
  • Standby saving mode can be selected
  • Front panel indicator for operation status
  • Thermostatically controlled cooling fan
  • Battery low alarm, battery low shutdown, over voltage, over temperature, output short, input polarity reverse, over load protections
  • Built in cooling fan ON-OFF control
  • Optional monitoring software
  • Output AC voltage selectable by setting button
  • 100 ~ 120VAC Output version available
  • Worldwide AC output receptacle options available
TS-1000 is a high performance true sine wave DC/AC power inverter that uses high frequency circuit topology. With high efficiency up to 92% this dc/ac inverter can provide 1000W continuously and peak load of 1150W for 3 minutes, 1500W for 10 seconds or 2000W surge power for 30 utility cycles.

Additional information

Manufacturer MEAN WELL
Standards
Type DC/AC
Outputs Single
  • Home appliances
  • power tools
  • office equipment
  • portable equipment
  • vehicles
  • yachts
OUTPUT
Rated Power1000W
Maximum Output Power1150W for 180 sec./1500W for 10 sec./surge power 2000W for 30 cycles
AC Voltage200/220/230/240VAC selectable by setting button
Frequency50±0.1%Hz 50/60Hz selectable by setting button S.W
WaveformtRUE SINE WAVE (thd<3%) at rated input voltage
AC Regulation±3.0%
Saving ModeLoad <5W will be changed to standby mode
Front Panel IndicatorBattery voltage level, output load level, saving mode, fault and operation status
***************************
INPUTSee table below for model specifics
No Load Dissipation<6W @ standby saving mode
Off Mode Current Draw<1mA
Battery TypesOpen & sealed lead acid
Input Bat. Polarity ProtectionBy internal fuse open
***************************
Over Temperature Protection65°C ±5°C
Shut down o/p voltage, re-power on to recover;
by internal RTH3 detect on heatsink of power transistor
Output Short ProtectionShut down o/p voltage, re-power on to recover
Over Load Protection105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Shut down o/p voltage, re-power on to recover
GFCI ProtectionNone
Working Temperature0°C ~ 40°C @ 100% load
Working Humidity20% ~ 90% RH non-condensing
Storage Temperature, Humidity-30°C ~ +70°C/-22°F ~ +158°F, 10 ~ 95% RH
Vibration10 ~ 500Hx, 5G 10min./1 cycle, 60 min. each along X, Y, X axes
Withstand VoltageBat I/P-AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
Isolation ResistanceBat I/P-AC O/P, Bat I/P-FG:100M Ohms/500VDC
Safety StandardsEN60950-1
EMCCompliance to EN55022 Class A, 72/245/ CEE, 95/54/ CE, E-Mark,
EN61000-4-2, 3, 8; ENV50204
Part NoInput Bat. VoltageInput Volt. RangeInput DC CurrentEff.Fuse ProtectionBat. Low AlarmBat. Low Shutdown
TS-1000-212D12V10.5 ~ 15VDC100A90%40A*211.3±4%10.5±4%
TS-1000-224D24V21 ~ 30VDC50A91%40A*222.5±4%21±4%
TS-1000-248D48V42 ~ 60VDC25A92%20A*245±4%42±4%