Features
- 2:1 input range, input and output isolation
- Input under voltage protection
- Input polarity reverse protection
- Soft start function, low inrush current
- Over load, over voltage, short circuit protection
- Output voltage ±10% adjustment
- No minimum load requirement
- 100% 50°C burn-in test
- Meets UL, cUL, TUV standards
Additional information
Manufacturer | |
---|---|
Standards | CE |
Type | DC/DC |
Outputs | Single |
Input Range | 36Vdc ~ 72Vdc (Typically 48V) |
Input Current | <2.4A @36V full load |
Input Voltage Protection | 4A/250V |
Over Voltage Protection | Unit will shutdown if an over voltage conditions occurs. Auto recovery once fault is removed |
Over Load Protection | 105% ~ 180% of rated output. Auto recovery |
Short Circuit Protection | Shutdown if a short circuit conditions occurs. Auto recovery once fault is removed |
Input Voltage Protection | <32V~35V |
Rise Time | <20ms |
Cooling | Natural cooling |
Operation Temperature | -10°C to +70°C, derating: 45°C~70°C: 2.5%/°C |
Operation Humidity | 20% to 85% RH non condensing |
Storage Temperature | -10°C to +75°C |
Storage Humidity | 10%~95% non condensing |
MTBF | 417K hours |
Safety | UL 60950-1, CSA C22.2 No.60950-1 , TUV EN 60950-1:2001, IEC 60950-1, EMKO-TSE(74-SEC)207/94 standard |
EMC | EN 55022 CLASS B、FCC CFR 47 PART 15 CLASS B、CNS 13438 CLASS B |
EN 55024:EN 61000-4-2,3,4,5,6,8 |
Part No | Voltage | Max Load | Regulation | Ripple Noise | Eff. | Max Power | OVP |
---|---|---|---|---|---|---|---|
SDS-060C3-3 | 3.3V | 15A | ±3% | 50mV | 68% | 50W | 3.8V ~ 4.6V |
SDS-060C05 | 5V | 12A | ±2% | 50mV | 76% | 60W | 5.8V ~ 7.0V |
SDS-060C12 | 12V | 5A | ±1% | 100mV | 80% | 60W | 13.8V ~ 17.5V |
SDS-060C24 | 24V | 2.5A | ±1% | 150mV | 82% | 60W | 27.6 ~ 33.6V |
SDS-060C48 | 48V | 1.3A | ±1% | 240mV | 82% | 60W | 55.2 ~ 67.2V |