Features
- 2:1 input range, input and output isolation
- Input under voltage protection
- Input polarity reverse protection
- Soft start function, low inrush current
- Over load, over voltage, short circuit protection
- Output voltage ±10% adjustment
- No minimum load requirement
- 100% 50°C burn-in test
- Meets UL, cUL, TUV standards
Additional information
Manufacturer | |
---|---|
Standards | CE |
Type | DC/DC |
Outputs | Single |
Input Voltage | 9.5Vdc ~ 18Vdc (Typically 12V) |
Input Current | <10A@9.5Vdc |
Input Protection | Ceramic fuse 15A/125V |
Over Voltage Protection | Unit will shutdown if an over voltage conditions occurs. Auto recovery once fault is removed |
Over Load Protection | 105% ~ 180% of rated output. Auto recovery |
Short Circuit Protection | Unit will shutdown if a short circuit conditions occurs. Auto recovery once fault is removed |
Rise Time | <20ms |
Cooling | Natural cooling |
Operation Temperature | 0°C to +70°C, derating: 50°C~70°C: 2.5%/°C |
Storage Temperature | -10°C to +75°C |
Operation Humidity | 20% to 85% RH non condensing |
Storage Humidity | 10%~95% non condensing |
MTBF | 417K hours |
Safety | UL60950-1, CSA C22.2 No 60950-1, TUV EN 60 950-1, IEC 60950-1, EMKO-TSE (74-SEC)207/94 |
EMC | EN 55022 CLASS B、FCC CFR 47 PART 15 CLASS B、CNS 13438 CLASS B. |
CNS 13438 CLASS B; EN 55024:EN 61000-4-2,3,4,5,6,8. |
Part No | Voltage | Max Load | Regulation | Ripple Noise | Eff. | Max Power | OVP |
---|---|---|---|---|---|---|---|
SDS-060A3-3 | 3.3V | 15A | ±3% | 50mV | 62% | 50W | 3.8 ~ 4.6V |
SDS-060A05 | 5V | 12A | ±2% | 50mV | 64% | 60W | 5.8 ~ 7.0V |
SDS-060A12 | 12V | 5A | ±1% | 100mV | 66% | 60W | 13.8 ~ 17.5V |
SDS-060A24 | 24V | 2.5A | ±1% | 150mV | 68% | 60W | 27.6 ~ 33.6V |
SDS-060A48 | 48V | 1.3A | ±1% | 240mV | 70% | 60W | 55.2 ~ 67.2V |